MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jdent.2024.104889

Медицинская библиотека · Journal of dentistry · 2024

Investigation of the accuracy of dynamic condylar position: A model study.

Xu Xinyu, Song Fengqi, Wu Ling, Zhang Leifeng, Liu Xiaojing

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate dynamic condylar positions by integrating mandibular movement recording data and cone-beam computed tomography (CBCT) and to investigate its accuracy via dynamic model experiments.

METHODS

A polyvinyl chloride skull model was utilized. A robot arm was used to operate the mandible to perform mouth opening, closing, protrusion, and lateral movements. A recording device, worn on the skull, was used to record the dynamic process and an optical position tracking (OPT) system was used to simultaneously trace the movements. A self-developed software module was used to evaluate the dynamic condylar position by integrating the dynamic tracing data and a virtual skull model derived from CBCT images. Errors were defined as differences between the dynamic coordinates of six landmarks around the condylar area derived from the software module (test) and OPT system (gold standard).

RESULTS

The condylar position errors were 0.76 ± 0.31, 0.55 ± 0.15, and 0.68 ± 0.23 mm for mouth opening, bilateral, and protrusion movements, respectively. Furthermore, the errors for small, moderate, and large mouth opening movements were 0.62 ± 0.19, 0.69 ± 0.29, and 0.94 ± 0.31 mm, respectively. The errors for all movements, except for large mouth opening, were significantly less than 1 mm (P < 0.05). The error was not different from 1 mm in the large mouth opening movement (P > 0.05).

CONCLUSIONS

Our developed method of achieving dynamic condylar position by integrating mandibular movement recording data and CBCT images is clinically reliable.

CLINICAL SIGNIFICANCE: This study proved the reliability of evaluating dynamic condylar position using a commercial dynamic recording instrument and CBCT images.

Для цитирования: Xu Xinyu, Song Fengqi, Wu Ling, Zhang Leifeng, Liu Xiaojing. Investigation of the accuracy of dynamic condylar position: A model study.. Journal of dentistry. 2024. DOI: 10.1016/j.jdent.2024.104889.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.