MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5009/gnl16079

Медицинская библиотека · Gut and liver · 2017

Magnetic Resonance Elastography and Diffusion Weighted Imaging in the Evaluation of Hepatic Fibrosis in Chronic Hepatitis B.

Hennedige Tiffany P, Wang Gang, Leung Fiona P, Alsaif Hind S, Teo Lynette Ls, Lim Seng Gee, Wee Aileen, Venkatesh Sudhakar K

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: Comparison of the accuracy of magnetic resonance elastography (MRE) and diffusion weighted imaging (DWI) for the diagnosis of liver fibrosis in patients with chronic hepatitis B (CHB).

METHODS

In this retrospective analysis, we investigated 63 patients with CHB and liver fibrosis. DWI was performed with both breath-hold (DWI-BH) and free-breathing (DWI-FB) sequences (b=0, 500). The mean liver stiffness and apparent diffusion coefficient (ADC) were calculated by drawing regions of interest maps. Fibrosis staging according to the METAVIR system was independently performed by an experienced pathologist. A receiver operating curve (ROC) analysis was conducted to determine the accuracy of MRE, DWI-BH and DWI-FB in the detection and stratification of liver fibrosis. The performance of the detection of significant fibrosis (≥F2), advanced fibrosis (≥F3), and cirrhosis (F4) was also evaluated by comparing areas under the ROC.

RESULTS

There was a moderate and significantly negative correlation between the ADC values and liver stiffness. The accuracies for the detection of ≥F2/≥F3/F4 stage fibrosis with DWI-FB, DWI-BH and MRE were 0.84/0.76/0.72, 0.72/0.83/0.79 and 0.99/0.99/0.98, respectively. The performance of MRE was significantly better than DWI-FB and DWI-BH. There were no significant differences between the performance of DWI-FB and DWI-BH.

CONCLUSIONS

MRE is more accurate than DWI for the detection and stratification of liver fibrosis in CHB.

Для цитирования: Hennedige Tiffany P, Wang Gang, Leung Fiona P, Alsaif Hind S, Teo Lynette Ls, Lim Seng Gee, Wee Aileen, Venkatesh Sudhakar K. Magnetic Resonance Elastography and Diffusion Weighted Imaging in the Evaluation of Hepatic Fibrosis in Chronic Hepatitis B.. Gut and liver. 2017. DOI: 10.5009/gnl16079.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.