MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Annals of the Royal College of Surgeons of England · 1989

Some clinical and technical aspects of circular stapled anastomoses of rectum and oesophagus.

Dickson G H

СтатьяПеревод пока не подготовлен

Аннотация

A complete 8-year experience using the circular stapling instrument is described; 109 rectal and 59 oesophageal anastomoses were performed. Intra-operative problems included two suspected rectal leaks, damage to the tissues in two patients when using too large an instrument, cardiac arrythmias in one patient, precipitated by contact between the heart and the instrument, one instrument/operator failure, and inversion of the muscle layer was incomplete in three oesophageal anastomoses. Postoperative complications included two leaks, seven strictures, seven abscesses and one patient required reoperation. There were no deaths attributable to the use of the instrument or the method of anastomosis. The instrument has allowed satisfactory anastomoses to be performed in relatively inaccessible sites.

Для цитирования: Dickson G H. Some clinical and technical aspects of circular stapled anastomoses of rectum and oesophagus.. Annals of the Royal College of Surgeons of England. 1989.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.