Infusion line contamination in preterm neonates: impact of infusion line design, length, and use duration: the multicenter ChronoBIOline study.

Dos Santos Sandra, Valentin Anne-Sophie, Farizon Mathilde, Charbonneau Manon, Boukhris Mohamed Riadh, Brat Roselyne, Cazzorla Fabiana, Chauvel Jennifer, Cneude Fabrice, Coutable Pauline, Demasure Maryvonne, Duminil Emeline, Faraut-Derouin Vénonique, Muselli Maud Gits, Gorin Valérie, Goujon Rosemary, Guillouche-Puissant Melinda, Hacinlioglu Nadine, Landelle Caroline, Lefebvre Annick, Leroy-Terquem Elise, Martinet Aurore, Massebeuf Camille, Orfanos Nadia Mazille, Menard Guillaume, Menvielle Laure, Monin Vanessa, Morange Virginie, Patkai Juliana, Perrault Nathalie, Prat Emilie, van der Mee-Marquet Nathalie

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Central venous catheters are critical in preterm neonatal care but increase the risk of central line-associated bloodstream infections (CLABSIs). The incidence of S. haemolyticus-associated CLABSIs in French neonates is increasing, but the mechanisms underlying this trend remain unclear.

METHODS

We examined microorganisms in 108 central line infusion sets used in preterm infants across 12 neonatal intensive care units, and collected at the time of removal.

RESULTS

The infusion sets varied widely in type (28 types; 1-6 parts) and length (10-180 cm, mean 52.9 cm). Contamination was detected in 24 infusion sets (22.2%), mainly by coagulase-negative Staphylococci (50.0%) and Bacillus species (41.7%). Higher contamination rates were linked to longer infusion lines (> 50 cm; p < 0.001), usage beyond 7 days (p = 0.002), and multi-line infusion systems (p < 0.001).

DISCUSSION: Our findings are fully consistent with guidelines, which recommend simpler designs and a 4 or 7-day use of infusion sets, emphasizing the importance of adhering to these guidelines to reduce the risk of CLABSIs. Additionally, our findings raise concerns regarding the use of multi-line infusion systems. These devices, which combine extended infusion line length, manufacturer-authorized use of up to 21 days, and intermittent use of certain infusion lines, are easily contaminated during use, creating a high-risk situation for central line contamination.

Для цитирования: Dos Santos Sandra, Valentin Anne-Sophie, Farizon Mathilde, Charbonneau Manon, Boukhris Mohamed Riadh, Brat Roselyne, Cazzorla Fabiana, Chauvel Jennifer, Cneude Fabrice, Coutable Pauline, Demasure Maryvonne, Duminil Emeline, Faraut-Derouin Vénonique, Muselli Maud Gits, Gorin Valérie, Goujon Rosemary, Guillouche-Puissant Melinda, Hacinlioglu Nadine, Landelle Caroline, Lefebvre Annick, Leroy-Terquem Elise, Martinet Aurore, Massebeuf Camille, Orfanos Nadia Mazille, Menard Guillaume, Menvielle Laure, Monin Vanessa, Morange Virginie, Patkai Juliana, Perrault Nathalie, Prat Emilie, van der Mee-Marquet Nathalie. Infusion line contamination in preterm neonates: impact of infusion line design, length, and use duration: the multicenter ChronoBIOline study.. Frontiers in microbiology. 2025. DOI: 10.3389/fmicb.2024.1495568.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.