BACKGROUND

In ENSURE-AF study, edoxaban had similar efficacy and safety profile versus enoxaparin-warfarin (enox-warf) in patients undergoing electrical cardioversion of non-valvular atrial fibrillation.

OBJECTIVES

To evaluate the efficacy and safety of edoxaban versus enox-warf in patients who were vitamin K antagonists (VKA) naïve or experienced at time of randomisation into ENSURE-AF trial.

METHODS

The primary efficacy endpoint was a composite of stroke, systemic embolic event, myocardial infarction, and cardiovascular death during the overall study period, 28 days on study drug after cardioversion and 30 days follow-up. The primary safety endpoint was the composite of major and clinically relevant nonmajor bleeding during the on-medication period from time of first dose to last dose of study drug taken + 3 days.

RESULTS

Of 2199 patients enrolled in ENSURE-AF, 1095 were randomised to edoxaban and 1104 to enox-warf. There were numerically fewer primary efficacy endpoint events with edoxaban than enox-warf irrespective of whether VKA experienced or naïve (0.5% vs. 0.9%, 0.3% vs. 1.4%, respectively). There were no significant differences in the primary safety endpoint [odds ratio (OR) 2.09, 95% confidence interval (CI) 0.72-6.81 in anticoagulant experienced patients, OR 0.77, 95% CI 0.15-3.60 in anticoagulant naïve patients] and in major bleeding rates regardless of treatment or VKA experience (OR 0.69, 95%CI 0.06-6.04, OR 0.48, 95% CI 0.01-9.25, respectively).

CONCLUSIONS

Edoxaban had comparable efficacy and safety to optimized anticoagulation with enox-warf. The primary efficacy and safety endpoint outcomes were broadly similar between VKA experienced or naïve patients.

Для цитирования: Kozieł Monika, Al-Saady Naab, Hjortshøj Søren P, Goudev Assen, Huber Kurt, Cohen Ariel, Jin James, Melino Michael, Winters Shannon M, Goette Andreas, Lip Gregory Y H. Edoxaban versus warfarin in vitamin K antagonist experienced and naïve patients from the edoxaban versus warfarin in subjects undergoing cardioversion of atrial fibrillation (ENSURE-AF) randomised trial.. Clinical research in cardiology : official journal of the German Cardiac Society. 2020. DOI: 10.1007/s00392-019-01594-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.