Аннотация

PURPOSE: Intestinal ultrasound (IUS) is used to assess and monitor inflammatory bowel disease (IBD). Bowel wall thickness (BWT) is its key marker, but accurate measurement is operator-dependent and requires expertise. Artificial intelligence (AI) may reduce variability and support IUS implementation. We developed and validated an AI model to detect bowel wall layers and measure BWT.

MATERIALS AND

METHODS

We developed a deep learning system (BowelAssist, BA) based on a pretrained convolutional neural network. A dataset of 9000 images (711 patients, 421 IBD) was used for training (80%), validation (10%), and testing (10%). Ground-truth annotations of bowel wall layers for 3000 segments were provided by an expert sonographer. External validation was performed live in 35 patients (67 bowel segments), with additional blinded evaluation by a trained operator in 19 (30 segments). BA performance, including BWT measurement, wall-layer recognition, and intra- and inter-observer agreement, was compared with manual measurements using Pearson's correlation and Bland-Altman analysis.

RESULTS

BA analysis was feasible in 94.7% of measurements. It showed excellent agreement with manual BWT measurements (r=0.88 for cross-sectional and r=0.77 for longitudinal scans), and low mean absolute errors (<0.45mm). The sensitivity and specificity for detecting pathological BWT were 83.6% and 95.7%, respectively. The intra-observer reproducibility of BA measurements was >0.90 and the inter-observer reproducibility between expert and trained operators was 0.53 for cross-sectional and 0.57 for longitudinal scans. Stratification recognition showed sensitivity of 90.1% and specificity of 83.8%.

CONCLUSION

An AI-based model provides accurate, reproducible assessment of BWT supporting its integration into clinical and research workflows for objective evaluation of IBD activity.

Для цитирования: Maconi Giovanni, Cassella Davide Giuseppe, Natalello Gabriele, Marra Antonella, Cataletti Giovanni, Anand Pradeep Kumar. Development and Clinical Validation of an Automated Artificial Intelligence System for Bowel Wall Thickness Assessment in Adult Inflammatory Bowel Diseases.. Ultraschall in der Medizin (Stuttgart, Germany : 1980). 2026. DOI: 10.1055/a-2870-0924.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.