MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcha.2025.101803

Медицинская библиотека · International journal of cardiology. Heart & vasculature · 2025

Increased dose of adenosine and the relationship between the resting full-cycle ratio and fractional flow reserve.

Christensen Christian A, Trøan Jens, Hansen Kirstine N, Noori Manijeh, Junker Anders, Veien Karsten, Christensen Martin K, Ellert-Gregersen Julia, Wachtell Kristian, Hansen Henrik S, Lassen Jens F, Qanie Diyako, Hougaard Mikkel, Jensen Lisette O

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Intermediate coronary artery stenosis can be evaluated with fractional flow reserve (FFR) and resting full-cycle ratio (RFR) to determine if the stenosis is functionally significant. However, RFR and FFR have shown discordance in around 20% of examinations. One explanation could be that maximal hyperemia was not achieved during adenosine infusion. The aim was to investigate if increased doses of adenosine would reduce FFR further, and if the agreement between RFR and FFR would improve.

METHOD: Two hundred patients underwent physiological assessment of an intermediate stenosis with RFR and FFR at 140 µg/kg/min (FFR140) and 200 µg/kg/min (FFR200) of adenosine infusion. The microcirculation function was assessed using the index of microvascular resistance (IMR).

RESULTS

Median RFR was 0.89 (interquartile range [IQR] 0.85-0.93). Median FFR decreased significantly during increased adenosine doses: FFR140 = 0.85 (IQR 0.77-0.90) versus FFR200 = 0.82 (IQR 0.75-0.87), p < 0.001. Reduction in FFR during increased adenosine doses was higher in patients with IMR ≥ 24 (FFR140 0.85 [IQR 0.78-0.92] versus FFR200 0.82 [IQR 0.75-0.86], p < 0.001) compared to patients with IMR < 24 (FFR140 0.83 [IQR 0.77-0.89] versus FFR200 0.81 [IQR 0.75-0.87], p < 0.001) with an absolute difference of -0.03 (-0.05, -0.01) versus -0.01 (-0.02, 0.0), p < 0.001. Area under the curve (AUC) of RFR compared to FFR140 was 0.88 (95 % confidence interval [CI] 0.84-0.93), and for FFR200, AUC was 0.88 (CI: 0.84-0.93).

CONCLUSION

Increased doses of adenosine significantly reduced FFR values, whereas the correlation agreement between RFR and FFR was not improved.

Для цитирования: Christensen Christian A, Trøan Jens, Hansen Kirstine N, Noori Manijeh, Junker Anders, Veien Karsten, Christensen Martin K, Ellert-Gregersen Julia, Wachtell Kristian, Hansen Henrik S, Lassen Jens F, Qanie Diyako, Hougaard Mikkel, Jensen Lisette O. Increased dose of adenosine and the relationship between the resting full-cycle ratio and fractional flow reserve.. International journal of cardiology. Heart & vasculature. 2025. DOI: 10.1016/j.ijcha.2025.101803.