The Post-Ureteroscopic Lesion Scale (PULS): a multicenter video-based evaluation of inter-rater reliability.
Аннотация
PURPOSE: The Post-Ureteroscopic Lesion Scale (PULS) offers a simple grading system for the description of ureteral lesions after ureteroscopy. In this article, we present the results of a video-based multicenter evaluation of the inter-rater reliability of clinically important PULS grades 0-3.
METHODS
Video sequences at the end of ureteroscopy (final passage) were recorded for 100 consecutive patients at a single institution and assessed by experienced urologists (n = 20) and senior residents (n = 17) at 19 international centers. The cohort included only patients with lesions grades 0-3 (with grades 2 and 3 subsumed as 2 + since distinction is defined by an extravasation of contrast medium in fluoroscopy). The gradings were evaluated for inter-rater reliability and in terms of simplicity, validity, comprehensibility, reproducibility, and usefulness.
RESULTS
Overall, inter-rater reliability was high (Kendall's W = 0.69, p < 0.001) and was comparable between specialists (Kendall's W = 0.69, p < 0.001) and residents (Kendall's W = 0.71, p < 0.001). The matched ratings showed grade 0 in 43.0 % of patients and grades 1 or 2 + in 44.0 and 13.0 % of patients, respectively. Results of the questionnaires indicated a high degree of acceptance, with an overall rating of 1.76 (1.64-1.93 for different items, scale 1-6).
CONCLUSIONS
Inter-rater reliability of the endoscopically assessable PULS was high among urologists with different levels of experience in different countries worldwide. The validated PULS system may be used for standardized reporting of ureteral lesions/injuries after ureteroscopy. In addition, PULS will enable more selective standardization of indications for postoperative DJ stenting based on the randomized controlled trials.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.