Radical cystectomy with W-shaped orthotopic ileal neobladder constructed with non-absorbable titanium staples-long term follow-up.

Kravchick Sergey, Lobik Leonid, Paz Adrian, Stepnov Eugeny, Ben-Dor David, Cytron Shmuel

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSES: We retrospectively assessed our experience with the W-shaped orthotopic ileal pouch, which was constructed with non-absorbable titanium staples. For these purpose, we discuss the results of bladder capacity, urinary continence and early and long-term postoperative complications.

MATERIALS AND

METHODS

We included in the study 17 patients who underwent radical cystoprostatectomy followed by construction of an orthotopic W-shaped ileal pouch between October 2000 and November 2009. A 65-70 cm segment of ileum was isolated and prearranged into a W-configuration, leaving two 10 cm intact segments on both sides of the ileal fragment. In our technique we entirely anatomized all adjacent limbs in order to create a sphere-shaped pouch. The ureters were directly anastomized to both intact segments of the ileal division. All our patients underwent pouchscopy 6 months after operation and annually.

RESULTS

Mean operative time for neobladder reconstruction and ureteral anastomoses was 87 ± 7.67 minutes. In one patient a leak from the ileo-ileal anastomosis was confirmed on the 3rd day after operation. In 2 cases unilateral stricture of the ureteral-neobladder anastomosis was documented. Staple lines were mostly covered with ileal mucosa after 6 months. The mean functional bladder capacity was 340 ± 27.6 mL and 375 ± 43.4 mL at 6 and 12 months, respectively. First-year daytime and nighttime continence was good and acceptable in 90% and 78% of patients, while it increased to 95% during the 2nd year.

CONCLUSIONS

The long term follow-up shows that non-absorbable titanium staples can be safely used for creation of an orthotopic ileal neobladder. However, these data should be further validated in a larger series of patients.

Для цитирования: Kravchick Sergey, Lobik Leonid, Paz Adrian, Stepnov Eugeny, Ben-Dor David, Cytron Shmuel. Radical cystectomy with W-shaped orthotopic ileal neobladder constructed with non-absorbable titanium staples-long term follow-up.. International braz j urol : official journal of the Brazilian Society of Urology. 2013. DOI: 10.1590/s1677-5538.ibju.2013.02.03.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.