First clinical evaluation of a new innovative ureteral access sheath (Re-Trace™): a European study.

Doizi Steeve, Knoll Thomas, Scoffone Cesare M, Breda Alberto, Brehmer Marianne, Liatsikos Evangelos, Cornu Jean-Nicolas, Traxer Olivier

Сравнительное исследованиеОценочное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The use of a ureteral access sheath (UAS) during flexible retrograde intrarenal surgery (RIRS) has become increasingly popular. Our aim was to evaluate the accessibility of a new UAS device, allowing the transformation of the working guidewire into a safety guidewire.

METHODS

A prospective, multicenter study was conducted between January and February 2010 in six European tertiary reference centers. Patients needing flexible RIRS were eligible to participate in the study. In all cases, insertion of the Re-Trace™ (12/14Fr, Coloplast, Denmark) was attempted at the beginning of the procedure. Insertion success was defined as placement of the UAS in the lumbar ureter with successful disengagement of the working guidewire, which turned into a safety guidewire. Influence of gender and pre-stenting status was analyzed by univariate analysis.

RESULTS

137 UASs were used in 75 male and 62 female patients. 25.5% of ureters were pre-stented: men were 2.17 more often pre-stented than women. The overall Re-Trace™ insertion rate was 82.5%. Success rate was not significantly different between men and women (77.3 vs. 88.7%, respectively, p = 0.11). Pre-stenting status did not significantly influence the success rate (p = 0.31). When analyzing the combined influence of pre-stenting status and gender, the worst success rates seemed to be obtained in men without pre-stenting, but no significant differences were found between groups.

CONCLUSIONS

Re-Trace™ UAS showed good overall insertion rates. This evaluation validated the new concept of guidewire disengagement: A single wire automatically switches from working to safety role.

Для цитирования: Doizi Steeve, Knoll Thomas, Scoffone Cesare M, Breda Alberto, Brehmer Marianne, Liatsikos Evangelos, Cornu Jean-Nicolas, Traxer Olivier. First clinical evaluation of a new innovative ureteral access sheath (Re-Trace™): a European study.. World journal of urology. 2013. DOI: 10.1007/s00345-013-1094-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.