MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/02676591261476511

Медицинская библиотека · Perfusion · 2026

Serum aquaporin-1 increases with heart failure and aortic valve surgery with cardiopulmonary bypass.

Politi María Teresa, Blanco Mailén, Fonseca Sebastián Raúl, Ferreyra Raúl, Bortman Guillermo, Piazza Antonio, Di Giusto Gisela, Capurro Claudia

СтатьяПеревод в очереди

Аннотация

IntroductionSerum aquaporin-1 increases with inflammation and edema. However, its role as a cardiovascular biomarker remains unexplored. The goal of this study is to evaluate serum aquaporin-1 concentrations across two distinct clinical settings characterized by myocardial stress and congestion: acute heart failure and surgical aortic valve replacement with cardiopulmonary bypass.MethodsThis observational study included healthy volunteers (n = 8), acute heart failure patients (n = 11), and surgical aortic valve replacement patients (n = 11). Serum aquaporin-1 was measured using ELISA. Myocardial biopsies were obtained for aquaporin-1 and aquaporin-4 protein quantification before and after cardiopulmonary bypass in six patients.ResultsSerum aquaporin-1 levels were significantly higher in acute heart failure (3,921 ± 1,396 pg/mL; p = 0.0006) and surgical aortic valve replacement patients (3,318 ± 1,394 pg/mL; p = 0.0070) compared to healthy volunteers (1,755 ± 807 pg/mL). These differences remained significant after adjusting for sex and age. All patients with low cardiac output had serum aquaporin-1 concentrations in the upper half of their group distribution. Serum aquaporin-1 correlated moderately with B-type natriuretic peptide (r = 0.40; p = 0.0265), C-reactive protein (r = 0.42; p = 0.0203), and erythrocyte sedimentation rate (r = 0.45; p = 0.0117). Following cardiopulmonary bypass, myocardial aquaporin-1 increased (73%; p = 0.0310), while aquaporin-4 decreased (53%; p = 0.0440), with a strong but non-significant correlation between cardiac and serum aquaporin-1 changes.ConclusionSerum aquaporin-1 levels are elevated in acute heart failure and post-surgical aortic valve replacement patients, particularly in those with low cardiac output.

Для цитирования: Politi María Teresa, Blanco Mailén, Fonseca Sebastián Raúl, Ferreyra Raúl, Bortman Guillermo, Piazza Antonio, Di Giusto Gisela, Capurro Claudia. Serum aquaporin-1 increases with heart failure and aortic valve surgery with cardiopulmonary bypass.. Perfusion. 2026. DOI: 10.1177/02676591261476511.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.