m+Medelevator.RU
← Поиск публикаций
Zhonghua yi xue za zhi · 2019

[Application of a multi-material artifact reduction algorithm in a wide-detector CT in the evaluation of the portal venous angiography of postoperative TIPS and embolization].

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Su L, Liang P, Lü P J, Wang M Y, Gao J B

Аннотация

Objective: To assess the effect of monochromatic images and metal artifact reduction (MAR) on the image quality of spectral CT portal venous angiography in patients with operation of after the performing transjugular intrahepatic portosystemic stent shunt(TIPS) and embolization. Methods: From December 2017 to April 2018, the examination data of 28 patients with portal hypertension due to cirrhosis who underwent portal vein angiography 1 month after TIPS and embolization were prospectively collected. After spectral CT scanning in revolution CT, the monochromatic energy levels(60 keV, 120 keV), 60 keV + 120 keV, 120kV-like + 120 keV fused images combined with MAR algorithm were reconstructed. Quantitative parameters such as image artifact index (AI) and qualitative visual evaluation scores were recorded and compared. Results: The 120 keV monochromatic images showed the lowest AI value(30.8±8.5, 18.2±4.3) and highest metal artifacts reduction effect. The 60 keV monochromatic images showed the highest AI value (57.3±15.7, 32.1±7.9) and the lowest metal artifacts reduction effect. The AI value of 60 keV + 120 keV fused images was lower than that of 60 keV images(26.2%, 24.7%). The difference of AI value between each group was statistically significant(all P<0.05). The interobserver agreement in the subjective image scores was moderate with kappa value of 0.824. The overall image quality score of 60 keV + 120 keV fused image and the noise score of 120 kV-like+120 keV were higher than the remaining groups. The differences of the subjective scores among each group were statistically significant(all P<0.05). Conclusion: The spectral CT with MAR algorithm can effectively improve the image quality of portal vein angiography after the TIPS and embolization therapy and the 60 keV + 120 keV fused images can eliminate artifacts and ensure a clear display of blood vessels.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты