MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12893-019-0600-y

Медицинская библиотека · BMC surgery · 2019

Novel biodegradable magnesium alloy clips compared with titanium clips for hepatectomy in a rat model.

Urade Takeshi, Yoshida Toshihiko, Ikeo Naoko, Naka Kosuke, Kido Masahiro, Toyama Hirochika, Ueno Kimihiko, Tanaka Motofumi, Mukai Toshiji, Fukumoto Takumi

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The use of surgical metal clips is crucial for ligating vessels in various operations. The currently available metal clips have several drawbacks; they are permanent and interfere with imaging techniques such as computed tomography (CT) or magnetic resonance (MR) imaging and carry the potential risk of endo-clip migration. We recently developed a novel magnesium (Mg) alloy for biodegradable clips that reduces artifacts on CT imaging. This study aimed to examine the tolerance, biodegradability, and biocompatibility of the Mg alloy clips compared with those of standard titanium (Ti) clips in hepatectomy.

METHODS

Thirty Wistar rats were divided into two groups based on the clip used (groups A and B). The vascular pedicle, including hepatic artery, portal vein, bile duct, and hepatic vein of the left lateral lobe, was ligated with the Ti clip in group A or the Mg alloy clip in group B, and then the left lateral lobe was removed. The rats were sacrificed at 1, 4, 12, 24, and 36 weeks after surgery. Clinical and histological evaluations were performed. Absorption rate was calculated by measuring the clip volume.

RESULTS

Although the Mg alloy clips showed biodegradability over time, there were no significant differences in the serum concentration of Mg between the two groups. The remaining volume ratio of Mg alloy clips was 95.5, 94.3, 80.0, 36.2, and 16.7% at 1, 4, 12, 24, and 36 weeks, respectively. No side effects occurred. Most of the microscopic changes were similar in both groups.

CONCLUSIONS

The new biodegradable Mg alloy clips are safe and feasible in vessel ligation for hepatectomy in a rat model and reduce artifacts in CT imaging compared with the standard Ti clips.

Для цитирования: Urade Takeshi, Yoshida Toshihiko, Ikeo Naoko, Naka Kosuke, Kido Masahiro, Toyama Hirochika, Ueno Kimihiko, Tanaka Motofumi, Mukai Toshiji, Fukumoto Takumi. Novel biodegradable magnesium alloy clips compared with titanium clips for hepatectomy in a rat model.. BMC surgery. 2019. DOI: 10.1186/s12893-019-0600-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.