MedElevator Войти в исследования
← Поиск публикаций

DOI 10.64898/2026.05.26.26353794

Медицинская библиотека · medRxiv : the preprint server for health sciences · 2026

Breath volatile profiling reveals a diagnostic signature of MASLD in children.

Berna Amalia Z, Panganiban Jennifer, Liu Yang, Logan Joey, Russo Pierre, Aryal Aakanshya, Hafertepe Kathryn, Abu-Alreesh Sarah, DeBosch Brian, Stoll Janis, Odom John Audrey R

СтатьяПрепринтПеревод пока не подготовлен

Аннотация

BACKGROUND & AIMS: Metabolic Dysfunction-Associated Steatotic Liver Disease (MASLD) is the leading cause of chronic liver disease in children. However, accurate, noninvasive diagnostic tools remain limited. Current screening methods are invasive or lack sensitivity. Breath-based volatile organic compound (VOC) analysis offers a simple approach with potential for point-of-care screening. This study aimed to identify and validate breath VOC signatures of pediatric MASLD.

APPROACH &

RESULTS

We conducted a prospective IRB-approved cohort study at the Children's Hospital of Philadelphia (CHOP). Children aged 7-20 years with MASLD (n=22), as defined by hepatic steatosis either by liver biopsy or imaging and 1 cardiometabolic risk factor, and a control group without MASLD (n=20) were enrolled. Breath samples were collected using a standardized protocol and analyzed by untargeted comprehensive two-dimensional gas chromatography-mass spectrometry (GC×GC-MS). Machine learning and unsupervised clustering were applied to identify discriminatory VOCs and assess heterogeneity. Untargeted GC×GC-MS analysis identified a distinct breath VOC signature in children with MASLD compared with non-MASLD controls. A Random Forest model achieved a sensitivity of 73% and specificity of 65%, with AUC of 0.84. The VOC 2,4-dimethyl-1-heptene demonstrated strong diagnostic performance in the discovery cohort with a sensitivity of 85%, specificity of 77% and an AUC of 0.81. Unsupervised clustering revealed four MASLD subgroups with distinct volatile phenotypes associated with differences in liver enzymes and metabolic parameters. External validation in a second pediatric cohort confirmed reproducible reductions in o/p-xylene in subjects with MASLD.

CONCLUSIONS

Pediatric MASLD is associated with a reproducible breath VOC signature identified by untargeted GC×GC-MS. These findings support breath analysis as a scalable, noninvasive screening and stratification tool for pediatric MASLD and warrant validation in larger, longitudinal studies.

Для цитирования: Berna Amalia Z, Panganiban Jennifer, Liu Yang, Logan Joey, Russo Pierre, Aryal Aakanshya, Hafertepe Kathryn, Abu-Alreesh Sarah, DeBosch Brian, Stoll Janis, Odom John Audrey R. Breath volatile profiling reveals a diagnostic signature of MASLD in children.. medRxiv : the preprint server for health sciences. 2026. DOI: 10.64898/2026.05.26.26353794.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.