MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/bjr/tqag132

Медицинская библиотека · The British journal of radiology · 2026

A comparison of contrast-to-noise ratio of liver tumors between dynamic contrast-enhanced CT and respiration-tracked 4D-CT for radiotherapy targeting.

Yang Haechan J, Jensen Nikolaj K G, Beech Ben, Gaede Stewart, Wong Eugene, Lock Michael

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

We compare the contrast-to-noise ratio (CNR) of tumors on 4D-CT and DCE-CT and explore how DCE-CT can be used to enhance tumor delineation for radiotherapy targeting.

METHODS

A total of 18 intrahepatic lesions from 15 patients were included in this study. Eight patients with primary hepatocellular carcinoma, and 7 metastatic patients with a total of 10 tumors, underwent DCE-CT and respiration-tracked 4D-CT. Both 4D-CT and DCE-CT were acquired at 120 kVp, but with 600 and 1920 mAs, respectively. CNRs were calculated for each lesion in each image set and compared using a paired t-test.

RESULTS

DCE-CT image sets had CNRs that were higher than those of 4D-CT image sets. The improvement in CNR was significant for lesions that were metastatic rather than primary, for lesions that were smaller than the mean size (5.7 cm), and for lesions that had undergone prior treatment rather than those that had not.

CONCLUSIONS

Target volume delineation in liver radiotherapy is challenging due to the inherent low tumor CNR. DCE-CT significantly improves CNR in liver metastases compared to 4D-CT, the current standard for radiation treatment planning. Considerations for DCE-CT include patients with metastatic lesions, additional iodinated contrast, and CT dose.

ADVANCES IN KNOWLEDGE: DCE-CT combined with 4D-CT can offer advantages in delineating small, previously-treated metastatic tumors for radiotherapy.

Для цитирования: Yang Haechan J, Jensen Nikolaj K G, Beech Ben, Gaede Stewart, Wong Eugene, Lock Michael. A comparison of contrast-to-noise ratio of liver tumors between dynamic contrast-enhanced CT and respiration-tracked 4D-CT for radiotherapy targeting.. The British journal of radiology. 2026. DOI: 10.1093/bjr/tqag132.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.