MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/2471549219861185

Медицинская библиотека · Journal of shoulder and elbow arthroplasty · 2019

Clinical and Radiological Evaluation of Subscapular Suture Integrity in Reverse Shoulder Arthroplasty.

Almeida Alexandre, Agostini Daniel C, Raymondi Cristiano, Guarise Pedro, de Almeida Nayvaldo Couto, Stangherlini Guilherme A

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim was to establish a correlation between the integrity of a suture made in the subscapular tendon (SST), as assessed by an ultrasound examination, and its functionality, as assessed by clinical tests during the postoperative period following reverse shoulder arthroplasty (RSA). A secondary goal is to evaluate the presence and viability of the sutured SST.

METHODS

This is a retrospective study of 18 RSA patients in whom the SST was repositioned to the anterior face of the humeral osteotomy. The median time of the postoperative evaluation was 31 months. The clinical evaluation consisted of the Gerber lift-off test, the internal rotation (IR) lag sign test, and the abdominal compression test, as well as forward flexion (FF), external rotation (ER), and IR. All patients underwent shoulder ultrasounds to evaluate the SST presence and viability.

RESULTS

The SST was visualized in 13 patients (72.2%; 95% confidence interval [CI], 51.5-92.9). Of these 13 patients, the SST presented an altered fibrillar pattern in 5 patients (38.4%; 95% CI, 12.0-64.9) and was considered nonviable. There were no associations between SST viability and a positive Gerber's lift-off test (P = .480), a positive IR lag sign test (P = .480), or a positive abdominal compression test (P = .618). There were no significant differences in FF (P = .104), ER (P = .196), or IR (P = .374) mobility between patients with viable SSTs and those without viable SSTs.

CONCLUSION

It was not possible to demonstrate a correlation between the integrity of the SST repair based on the ultrasound and its functionality as assessed by clinical tests in the postoperative period following an RSA. The SST repair has a high failure rate, as demonstrated by the high incidence of nonviable or absent tendons.

Для цитирования: Almeida Alexandre, Agostini Daniel C, Raymondi Cristiano, Guarise Pedro, de Almeida Nayvaldo Couto, Stangherlini Guilherme A. Clinical and Radiological Evaluation of Subscapular Suture Integrity in Reverse Shoulder Arthroplasty.. Journal of shoulder and elbow arthroplasty. 2019. DOI: 10.1177/2471549219861185.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.