MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/pcc.0000000000002059

Медицинская библиотека · Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2019

Innovation in Central Venous Access Device Security: A Pilot Randomized Controlled Trial in Pediatric Critical Care.

Ullman Amanda J, Long Debbie, Williams Tara, Pearson Kylie, Mihala Gabor, Mattke Adrian C, Macfarlane Fiona, Rickard Claire M

СтатьяРандомизированное исследованиеEquivalence TrialПеревод пока не подготовлен

Аннотация

OBJECTIVES

Central venous access devices enable many treatments during critical illness; however, 25% of pediatric central venous access devices fail before completion of treatment due to infection, thrombosis, dislodgement, and occlusion. This is frequently attributed to inadequate securement and dressing of the device; however, high-quality research evaluating pediatric central venous access device securement innovation to prevent central venous access device failure is scarce. This study aimed to establish the feasibility of a definitive randomized control trial examining the effectiveness of current and new technologies to secure central venous access devices in pediatrics.

DESIGN

Single-center, parallel group, superiority, pilot randomized control trial.

SETTING

Anesthetic and intensive care departments of a tertiary pediatric hospital SUBJECTS:: One-hundred eighty pediatric patients with nontunneled central venous access device INTERVENTIONS:: Participants were randomized to receive central venous access device securement via standard care (bordered polyurethane dressing, with prolene sutures, chlorhexidine gluconate disc), tissue adhesive (Histoacryl, B Braun, Melsungen, Germany) in addition to standard care; or integrated dressing securement (SorbaView SHIELD [Centurion Medical Products, Franklin, MA], with prolene sutures and chlorhexidine gluconate disc).

OUTCOMES: Primary: Feasibility (including effect size estimates, acceptability); central venous access device failure; central venous access device complications; secondary: individual central venous access device complications, skin damage, dressing performance, and product cost.

MEASUREMENTS AND MAIN

RESULTS

Feasibility criteria were achieved as recruitment occurred with acceptable eligibility, recruitment, missing data, and attrition rates, as well as good protocol adherence. Family members and staff-reported comparable levels of acceptability between study arms; however, tissue adhesive was reported as the most difficult to apply. Overall, 6% of central venous access devices failed, including 6% (3/54; incident rate, 13.2 per 1,000 catheter days) standard care, 2% (1/56; incident rate, 3.65 per 1,000 catheter days) integrated, and 8% (5/59; 25.0 per 1,000 catheter days) tissue adhesive.

CONCLUSIONS

It is feasible to conduct an efficacy randomized control trial of the studied interventions. Further research is required to definitively identify clinical, cost-effective methods to prevent central venous access device failure by examining new dressing and securement technologies and techniques.

Для цитирования: Ullman Amanda J, Long Debbie, Williams Tara, Pearson Kylie, Mihala Gabor, Mattke Adrian C, Macfarlane Fiona, Rickard Claire M. Innovation in Central Venous Access Device Security: A Pilot Randomized Controlled Trial in Pediatric Critical Care.. Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies. 2019. DOI: 10.1097/pcc.0000000000002059.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.