MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2460/ajvr.80.7.709

Медицинская библиотека · American journal of veterinary research · 2019

In vitro evaluation of the knot-holding capacity and security, weight, and volume of forwarder knots tied with size-3 polyglactin 910 suture exposed to air, balanced electrolyte solution, or equine abdominal fat.

McGlinchey Leah, Boone Lindsey H, Munsterman Amelia S, Coleridge Matthew O D, Rosanowski Sarah M, Farag Ramsis, Hanson R Reid

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the effect of exposure to a balanced electrolyte solution (BES), or equine abdominal fat on the knot-holding capacity (KHC), relative knot security (RKS), weight, and volume of forwarder knots versus surgeon's knots.

SAMPLE: 315 knots tied and tested in vitro.

PROCEDURES: United States Pharmacopeia size-3 polyglactin 910 suture exposed to air (dry [control]), equine abdominal fat (fat-exposed), or BES (BES-exposed) was used to tie forwarder knots with 2, 3, and 4 throws and surgeon's knots with 5, 6, 7, and 8 throws. A universal materials testing machine was used to test the tensile strength of suture and knots to failure, and the KHC, RKS, weight, and volume of knots were determined.

RESULTS

Forwarder knots had significantly higher KHC and RKS and lower volume, compared with surgeons' knots. Forwarder knots tied with fat-exposed suture had greater weight, but not volume, than did forwarder knots tied with dry or BES-exposed suture with the same number of throws.

CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that forwarder knots were superior to surgeon's knots when configured as start knots intended for continuous lines of suture. Exposure to media did not negatively affect mechanical or physical properties of forwarder knots and may improve specific biomechanical functions, including KHC and RKS.

Для цитирования: McGlinchey Leah, Boone Lindsey H, Munsterman Amelia S, Coleridge Matthew O D, Rosanowski Sarah M, Farag Ramsis, Hanson R Reid. In vitro evaluation of the knot-holding capacity and security, weight, and volume of forwarder knots tied with size-3 polyglactin 910 suture exposed to air, balanced electrolyte solution, or equine abdominal fat.. American journal of veterinary research. 2019. DOI: 10.2460/ajvr.80.7.709.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.