BACKGROUND

The polyurethane nasolacrimal duct stent is used as an alternative to conventional techniques for treatment of lower tear duct obstruction. The aim of this study was to evaluate the clinical success rate after a follow-up of 2 years.

METHODS

Nasolacrimal duct stent implantation was attempted in 19 patients with nasolacrimal duct obstruction proven by digital substraction dacryocystography. The median age of the patients was 50 years, and the minimum duration of symptoms was 3 months. Patients were followed up 1 week, 6 months, 1 year and 2 years after the procedure.

RESULTS

Eighteen stents were implanted in 17 patients without surgical complications. All stents were proven to be patent at the end of the procedure. Success rate, defined as proportion of patients free of symptoms, was 66.6%, 55.5% and 50% after 1 week, 6 months and I year, respectively, and remained unchanged thereafter. Three stents had to be removed between 6 months and 2 years after implantation. Histological examination showed granulation tissue growing into the opening and obstructing the stent in one case.

CONCLUSION

Implantation of a polyurethane nasolacrimal duct stent is an alternative to conventional techniques in lower tear duct obstruction. Its overall success rate is lower than that reported after conventional dacryocystorhinostomy, but the procedure is fast, safe and reversible. Refinement of the surface and stent design may improve results in the future.

Для цитирования: Schaudig U, Maas R. The polyurethane nasolacrimal duct stent for lower tear duct obstruction: long-term success rate and complications.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2000. DOI: 10.1007/s004170000187.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.