MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mrm.30274

Медицинская библиотека · Magnetic resonance in medicine · 2024

A 32-channel high-impedance honeycomb-shaped receive array for temporal lobes exploration at 11.7T.

Gapais Paul-François, Luong Michel, Giacomini Eric, Guillot Jules, Djaballah Elias, Gunamony Shajan, Chu Son, Hosseinnezhadian Sajad, Amadon Alexis

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The newly operational 11.7T Iseult scanner provides an improved global SNR in the human brain. This gain in SNR can be pushed even further locally by designing region-focused dense receive arrays. The temporal lobes are particularly interesting to neuroscientists as they are associated with language and concept recognition. Our main goal was to maximize the SNR in the temporal lobes and provide high-acceleration capabilities for fMRI studies.

METHODS

We designed and developed a 32-channel receive array made of non-overlapped hexagonal loops. The loops were arranged in a honeycomb pattern and targeted the temporal lobes. They were placed on a flexible neoprene cap closely fitting the head. A new stripline design with a high impedance was proposed and applied for the first time at 11.7T. Specific homebuilt miniaturized low-impedance preamplifiers were directly mounted on the loops, providing preamplifier decoupling in a compact and modular design. Using an anatomical phantom, we experimentally compared the SNR and parallel imaging performance of the region-focused cap to a 32-channel whole-brain receive array at 11.7T.

RESULTS

The experimental results showed a 1.7-time higher SNR on average in the temporal lobes compared to the whole brain receive array. The g-factor is also improved when undersampling in the antero-posterior and head-foot directions.

CONCLUSION

A significant SNR boost in the temporal lobes was demonstrated at 11.7T compared to the whole-brain receive array. The parallel imaging capabilities were also improved in the temporal lobes in some acceleration directions.

Для цитирования: Gapais Paul-François, Luong Michel, Giacomini Eric, Guillot Jules, Djaballah Elias, Gunamony Shajan, Chu Son, Hosseinnezhadian Sajad, Amadon Alexis. A 32-channel high-impedance honeycomb-shaped receive array for temporal lobes exploration at 11.7T.. Magnetic resonance in medicine. 2024. DOI: 10.1002/mrm.30274.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.