DOI 10.1177/0309364616640949

Медицинская библиотека · Prosthetics and orthotics international · 2016

Static load bearing exercises of individuals with transfemoral amputation fitted with an osseointegrated implant: Loading compliance.

Vertriest Sofie, Coorevits Pascal, Hagberg Kerstin, Brånemark Rickard, Häggström Eva Elisabet, Vanderstraeten Guy, Frossard Laurent Alain

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Load-bearing exercises are performed by transfemoral amputees fitted with an osseointegrated implant to facilitate bone remodelling.

OBJECTIVE

This study presents the loading compliance comparing loads prescribed and applied on the three axes of the implant during static load-bearing exercises with a specific emphasis on axial and vectorial comparisons.

STUDY

DESIGN

Cohort study.

METHODS

A total of 11 fully rehabilitated unilateral transfemoral amputees fitted with an osseointegrated implant performed five trials in four loading conditions using a static standing frame. The load prescribed was monitored using a vertical single-axis strain gauge connected to an electronic display. The tri-axial forces applied on the implant were measured directly with an instrumented pylon including a six-channel transducer. The analysis included 'axial' and 'vectorial' comparisons corresponding to the difference between the force applied on the long axis of the implant and the load prescribed as well as the resultant of the three components of the load applied and the load prescribed, respectively.

RESULTS

The results demonstrated that axial and vectorial differences were significant in all conditions ( p < 0.05), except for the vectorial difference for the 40 kg condition ( p = 0.182).

CONCLUSION

The significant lack of axial compliance led to systematic underloading of the long axis of the implant. Clinical relevance This study contributes to a better understanding of the load applied on an osseointegrated implant during the static load-bearing exercises that could contribute to improve the design of apparatus to monitor loading exercises as well as clinical guidelines for the loading progression during rehabilitation.

Для цитирования: Vertriest Sofie, Coorevits Pascal, Hagberg Kerstin, Brånemark Rickard, Häggström Eva Elisabet, Vanderstraeten Guy, Frossard Laurent Alain. Static load bearing exercises of individuals with transfemoral amputation fitted with an osseointegrated implant: Loading compliance.. Prosthetics and orthotics international. 2016. DOI: 10.1177/0309364616640949.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.