MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0954411915624452

Медицинская библиотека · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2016

Biomechanical design considerations for transradial prosthetic interface: A review.

Sang Yuanjun, Li Xiang, Luo Yun

СтатьяПоддержка исследования: вне правительства СШАОбзорПеревод пока не подготовлен

Аннотация

Traditional function and comfort assessment of transradial prostheses pay scant attention to prosthetic interface. With better understanding of the biomechanics of prosthetic interface comes better efficiency and safety for interface design; in this way, amputees are more likely to accept prosthetic usage. This review attempts to provide design and selection criteria of transradial interface for prosthetists and clinicians. Various transradial socket types in the literature were chronologically reviewed. Biomechanical discussion of transradial prosthetic interface design from an engineering point of view was also done. Suspension control, range of motion, stability, as well as comfort and safety of socket designs have been considered in varying degrees in the literature. The human-machine interface design should change from traditional "socket design" to new "interface design." From anatomy and physiology to biomechanics of the transradial residual limb, the force and motion transfer, together with comfort and safety, are the two main aspects in prosthetic interface design. Load distribution and transmission should mainly rely on achieving additional skeletal control through targeted soft tissue relief. Biomechanics of the residual limb soft tissues should be studied to find the relationship between mechanical properties and the comfort and safety of soft tissues.

Для цитирования: Sang Yuanjun, Li Xiang, Luo Yun. Biomechanical design considerations for transradial prosthetic interface: A review.. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine. 2016. DOI: 10.1177/0954411915624452.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.