MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euaa001

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2020

Clinical outcomes of Watchman vs. Amplatzer occluders for left atrial appendage closure (WATCH at LAAC).

Kleinecke Caroline, Yu Jiangtao, Neef Philip, Buffle Eric, de Marchi Stefano, Fuerholz Monika, Nietlispach Fabian, Valgimigli Marco, Streit Samuel R, Fankhauser Mate, Duenninger Erich, Windecker Stephan, Meier Bernhard, Gloekler Steffen

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: This study compares clinical outcomes of Watchman vs. Amplatzer devices for left atrial appendage closure (LAAC).

METHODS AND

RESULTS

Of two real-world registries, the Watchman registry Lichtenfels, Germany, and the Amplatzer registry Bern-Zurich, Switzerland, 303 and 333 consecutive patients, respectively, were included. After a 1:1 propensity score matching, 266 vs. 266 patients were compared by use of the predefined primary efficacy endpoint of stroke, systemic embolism and cardiovascular/unexplained death, the primary safety endpoint of major peri-procedural complications and major bleeding events at follow-up, and the combined hazard endpoint, a composite of all above-mentioned hazards. Mean age was 75.3 ± 7.8 (Watchman) vs. 75.1 ± 9.9 (Amplatzer) years, CHA2DS2-VASc score 4.5 ± 1.7 vs. 4.5 ± 1.5, and HAS-BLED score 3.2 ± 1.0 vs. 3.2 ± 1.0. At a mean follow-up of 2.4 ± 1.3 vs. 2.5 ± 1.5 years and 1.322 patient-years, the primary endpoints of efficacy [40/646, 6.2% [Watchman] vs. 43/676, 6.4% [Amplatzer]; hazard ratio (HR), 1.02; 95% confidence interval (CI), 0.66-1.58; P = 0.92] and safety (33/646, 5.1% vs. 30/676, 4.4%; HR, 0.57; 95% CI, 0.29-1.11; P = 0.10), as well as the combined hazard endpoint (69/646, 10.7% vs. 66/676, 9.8%; HR, 0.80; 95% CI, 0.55-1.12; P = 0.26) were similar for both groups.

CONCLUSION

This study suggests comparable efficacy and safety of the Watchman and Amplatzer devices.

Для цитирования: Kleinecke Caroline, Yu Jiangtao, Neef Philip, Buffle Eric, de Marchi Stefano, Fuerholz Monika, Nietlispach Fabian, Valgimigli Marco, Streit Samuel R, Fankhauser Mate, Duenninger Erich, Windecker Stephan, Meier Bernhard, Gloekler Steffen. Clinical outcomes of Watchman vs. Amplatzer occluders for left atrial appendage closure (WATCH at LAAC).. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2020. DOI: 10.1093/europace/euaa001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.