Comparison of 4-French versus 5-French sheaths for diagnostic coronary angiography via the snuffbox approach.
Аннотация
BACKGROUND
Although a shorter hemostasis duration would be expected when compared with the conventional radial approach as the diameter of the distal radial artery is smaller than that of the conventional radial artery, the optimal duration of hemostasis in diagnostic coronary angiography (CAG) via the distal radial approach, termed the snuffbox approach, has not been well investigated.
METHODS
Data from 171 patients were retrospectively collected (55 and 116 patients in the 4-French [Fr] and 5-Fr sheath groups, respectively). The patients had suspected myocardial ischemia and were undergoing diagnostic CAG via the snuffbox approach at a single center between January 2019 and August 2019.
RESULTS
The mean age of the study population was 67.6 ± 11.0 years, and 69% were male. The left snuffbox approach was performed in 146 (85.4%) patients. The mean snuffbox puncture time, defined as the time interval between local anesthesia and sheath cannulation, was 145.1 ± 120.8 s. The hemostasis duration was significantly shorter in the 4-Fr sheath group than in the 5-Fr sheath group (70 [62-90] vs. 120 [120-130] min; p < 0.001). There were local hematomas, defined as ≤ 5 cm in diameter, at the puncture site in 8 (4.7%) patients. Moreover, there were no conventional and distal radial artery occlusions, assessed by manual pulse, after hemostasis in the study population during hospitalization.
CONCLUSIONS
Successful hemostasis was obtained within 2 h for diagnostic CAG via the snuffbox approach using the 4-Fr or 5-Fr sheaths.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.