MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijrobp.2022.11.021

Медицинская библиотека · International journal of radiation oncology, biology, physics · 2022

Assessing Interobserver Variability in the Delineation of Structures in Radiation Oncology: A Systematic Review.

Guzene Leslie, Beddok Arnaud, Nioche Christophe, Modzelewski Romain, Loiseau Cedric, Salleron Julia, Thariat Juliette

Систематический обзорСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The delineation of target volumes and organs at risk is the main source of uncertainty in radiation therapy. Numerous interobserver variability (IOV) studies have been conducted, often with unclear methodology and nonstandardized reporting. We aimed to identify the parameters chosen in conducting delineation IOV studies and assess their performances and limits.

METHODS AND MATERIALS: We conducted a systematic literature review to highlight major points of heterogeneity and missing data in IOV studies published between 2018 and 2021. For the main used metrics, we did in silico analyses to assess their limits in specific clinical situations.

RESULTS

All disease sites were represented in the 66 studies examined. Organs at risk were studied independently of tumor site in 29% of reviewed IOV studies. In 65% of studies, statistical analyses were performed. No gold standard (GS; ie, reference) was defined in 36% of studies. A single expert was considered as the GS in 21% of studies, without testing intraobserver variability. All studies reported both absolute and relative indices, including the Dice similarity coefficient (DSC) in 68% and the Hausdorff distance (HD) in 42%. Limitations were shown in silico for small structures when using the DSC and dependence on irregular shapes when using the HD. Variations in DSC values were large between studies, and their thresholds were inconsistent. Most studies (51%) included 1 to 10 cases. The median number of observers or experts was 7 (range, 2-35). The intraclass correlation coefficient was reported in only 9% of cases. Investigating the feasibility of studying IOV in delineation, a minimum of 8 observers with 3 cases, or 11 observers with 2 cases, was required to demonstrate moderate reproducibility.

CONCLUSIONS

Implementation of future IOV studies would benefit from a more standardized methodology: clear definitions of the gold standard and metrics and a justification of the tradeoffs made in the choice of the number of observers and number of delineated cases should be provided.

Для цитирования: Guzene Leslie, Beddok Arnaud, Nioche Christophe, Modzelewski Romain, Loiseau Cedric, Salleron Julia, Thariat Juliette. Assessing Interobserver Variability in the Delineation of Structures in Radiation Oncology: A Systematic Review.. International journal of radiation oncology, biology, physics. 2022. DOI: 10.1016/j.ijrobp.2022.11.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.