BACKGROUND

Treatment response assessment in patients with brain metastasis uses contrast enhanced T1-weighted MRI. Advanced MRI techniques have been studied, but the diagnostic accuracy is not well known. Therefore, we performed a metaanalysis to assess the diagnostic accuracy of the currently available MRI techniques for treatment response.

METHODS

A systematic literature search was done. Study selection and data extraction were done by two authors independently. Meta-analysis was performed using a bivariate random effects model. An independent cohort was used for DSC perfusion external validation of diagnostic accuracy.

RESULTS

Anatomical MRI (16 studies, 726 lesions) showed a pooled sensitivity of 79% and a specificity of 76%. DCE perfusion (4 studies, 114 lesions) showed a pooled sensitivity of 74% and a specificity of 92%. DSC perfusion (12 studies, 418 lesions) showed a pooled sensitivity was 83% with a specificity of 78%. Diffusion weighted imaging (7 studies, 288 lesions) showed a pooled sensitivity of 67% and a specificity of 79%. MRS (4 studies, 54 lesions) showed a pooled sensitivity of 80% and a specificity of 78%. Combined techniques (6 studies, 375 lesions) showed a pooled sensitivity of 84% and a specificity of 88%. External validation of DSC showed a lower sensitivity and a higher specificity for the reported cut-off values included in this metaanalysis.

CONCLUSION

A combination of techniques shows the highest diagnostic accuracy differentiating tumor progression from treatment induced abnormalities. External validation of imaging results is important to better define the reliability of imaging results with the different techniques.

Для цитирования: Teunissen Wouter H T, Govaerts Chris W, Kramer Miranda C A, Labrecque Jeremy A, Smits Marion, Dirven Linda, van der Hoorn Anouk. Diagnostic accuracy of MRI techniques for treatment response evaluation in patients with brain metastasis: A systematic review and meta-analysis.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2022. DOI: 10.1016/j.radonc.2022.10.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.