Аннотация

PURPOSE: This study evaluated newly designed tests to measure near heterophoria, comparing them to the Maddox Wing and Howell card, and assessed whether accommodative responses differed between the different heterophoria test targets.

METHODS

Near horizontal heterophoria of 20 visually normal young adults was measured using the Maddox Wing, Howell Card and two versions of a newly designed Huddersfield Heterophoria Test (HHT) card. The HHT cards are based on the Prentice method, either with or without an additional spatially defined grating superimposed on the scale. The addition of a spatially defined grating has been suggested to control accommodation better. A single examiner was used to take measurements on two separate occasions, presenting each test in a random order. Monocular accommodative responses to each heterophoria target were also obtained in a separate session by another examiner.

RESULTS

Heterophoria measurements between the four tests were not significantly different, neither clinically nor statistically. Differences in test-retest measurements between test and retest conditions were small and not significantly different. Mean accommodative responses were also not significantly different between the test targets.

CONCLUSIONS

Differences in target configurations in the Maddox Wing, Howell card or new HHT cards did not influence accommodative responses in a sample of young adults. The newly designed HHT cards (or other variations of the Prentice method) may be used to measure near horizontal heterophoria in a young adult population either with or without additional horizontal lines superimposed on the scale.

Для цитирования: Siderov John, Theagarayan Baskar, Zahir Muneebah, Hynes Niall J. Additional accommodative controls in near heterophoria targets do not improve accommodative responses in young adults.. Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists). 2025. DOI: 10.1111/opo.13476.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.