MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/acm2.13793

Медицинская библиотека · Journal of applied clinical medical physics · 2022

The application of multiple metrics in deformable image registration for target volume delineation of breast tumor bed.

Xie Xin, Song Yuchun, Ye Feng, Yan Hui, Wang Shulian, Zhao Xinming, Dai Jianrong

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: For postoperative breast cancer patients, deformable image registration (DIR) is challenged due to the large deformations and non-correspondence caused by tumor resection and clip insertion. To deal with it, three metrics (fiducial-, region-, and intensity-based) were jointly used in DIR algorithm for improved accuracy.

MATERIALS AND

METHODS

Three types of metrics were combined to form a single-objective function in DIR algorithm. Fiducial-based metric was used to minimize the distance between the corresponding point sets of two images. Region-based metric was used to improve the overlap between the corresponding areas of two images. Intensity-based metric was used to maximize the correlation between the corresponding voxel intensities of two images. The two CT images, one before surgery and the other after surgery, were acquired from the same patient in the same radiotherapy treatment position. Twenty patients who underwent breast-conserving surgery and postoperative radiotherapy were enrolled in this study.

RESULTS

For target registration error, the difference between the proposed and the conventional registration methods was statistically significant for soft tissue (2.06 vs. 7.82, p = 0.00024 < 0.05) and body boundary (3.70 vs. 6.93, p = 0.021 < 0.05). For visual assessment, the proposed method achieved better matching result for soft tissue and body boundary.

CONCLUSIONS

Comparing to the conventional method, the registration accuracy of the proposed method was significantly improved. This method provided a feasible way for target volume delineation of tumor bed in postoperative radiotherapy of breast cancer patients.

Для цитирования: Xie Xin, Song Yuchun, Ye Feng, Yan Hui, Wang Shulian, Zhao Xinming, Dai Jianrong. The application of multiple metrics in deformable image registration for target volume delineation of breast tumor bed.. Journal of applied clinical medical physics. 2022. DOI: 10.1002/acm2.13793.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.