OBJECTIVE

Atlantooccipital fixation is an important technique in the treatment of upper cervical spine instability. Important considerations for implant devices are obtrusiveness and propagation of torque through the device caused by cervical rotation. The authors evaluated the feasibility of 3 regions of the occiput as sites for occipitocervical fixation by examining bone mineral density at these locations.

METHODS

Unembalmed occiputs of 9 male and 4 female cadavers were used (mean age at time of death was 61.6 years, range 36-68 years). Studies were undertaken using caliper measurements and dual-energy x-ray absorptiometry of the superior nuchal line (SNL), the external occipital protuberance (EOP), and the inferior nuchal line (INL).

RESULTS

Data indicate that the bone at the INL has a similar volumetric bone density as the bone at the SNL, despite having half the thickness. Also, the volumetric bone density increases laterally along the nuchal lines.

CONCLUSIONS

Most hardware fixation is centered on stabilization at the EOP and the SNL. On the basis of these radiological results, the INL shows promise as a potential alternative site for screw placement in occipitocervical fixation.

Для цитирования: Das Chandan, Newcomb Anna G U S, Gaudin Daniel P, Crawford Neil R. Densitometric comparison of 3 occipital regions for suitability of fixation.. Journal of neurosurgery. Spine. 2016. DOI: 10.3171/2015.7.spine141142.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.