Estimation of post-therapeutic liver reserve capacity using 99mTc-GSA scintigraphy prior to carbon-ion radiotherapy for liver tumors.

Yamazaki Kana, Nishii Ryuichi, Mizutani Yoichi, Makishima Hirokazu, Kaneko Takashi, Isobe Yoshiharu, Terada Tamasa, Tamura Kentaro, Imabayashi Etsuko, Tani Toshiaki, Kobayashi Masato, Wakatsuki Masaru, Tsuji Hiroshi, Higashi Tatsuya

СтатьяКомментарийПеревод пока не подготовлен

Аннотация

BACKGROUND

There is currently no established imaging method for assessing liver reserve capacity prior to carbon-ion radiotherapy (CIRT) for liver tumors. In order to perform safe CIRT, it is essential to estimate the post-therapeutic residual reserve capacity of the liver.

PURPOSE: To evaluate the ability of pre-treatment 99mTc-galactosyl human serum albumin (99mTc-GSA) scintigraphy to accurately estimate the residual liver reserve capacity in patients treated with CIRT for liver tumors.

MATERIALS AND

METHODS

This retrospective study evaluated patients who were performed CIRT for liver tumors between December 2018 and September 2020 and underwent 99mTc-GSA scintigraphy before and 3 months after CIRT, and gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI within 1 month before CIRT were evaluated. The maximal removal rate of 99mTc-GSA (GSA-Rmax) was analyzed for the evaluation of pre-treatment liver reserve capacity. Then, the GSA-Rmax of the estimated residual liver (GSA-RL) was calculated using liver SPECT images fused with the Gd-EOB-DTPA-enhanced MRI. GSA-RL before CIRT and GSA-Rmax at 3 months after CIRT were compared using non-parametric Wilcoxon signed-rank test and linear regression analysis.

RESULTS

Overall, 50 patients were included (mean age ± standard deviation, 73 years ± 11; range, 29-89 years, 35 men). The median GSA-RL was 0.393 [range, 0.057-0.729] mg/min, and the median GSA-Rmax after CIRT was 0.369 [range, 0.037-0.780] mg/min (P = .40). The linear regression equation representing the relationship between the GSA-RL and GSA-Rmax after CIRT was y = 0.05 + 0.84x (R2 = 0.67, P < .0001). There was a linear relationship between the estimated and actual post-treatment values for all patients, as well as in the group with impaired liver reserve capacity (y = - 0.02 + 1.09x (R2 = 0.62, P = .0005)).

CONCLUSIONS

99mTc-GSA scintigraphy has potential clinical utility for estimating the residual liver reserve capacity in patients undergoing carbon-ion radiotherapy for liver tumors.

TRIAL REGISTRATION: UMIN000038328, https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000043545 .

Для цитирования: Yamazaki Kana, Nishii Ryuichi, Mizutani Yoichi, Makishima Hirokazu, Kaneko Takashi, Isobe Yoshiharu, Terada Tamasa, Tamura Kentaro, Imabayashi Etsuko, Tani Toshiaki, Kobayashi Masato, Wakatsuki Masaru, Tsuji Hiroshi, Higashi Tatsuya. Estimation of post-therapeutic liver reserve capacity using 99mTc-GSA scintigraphy prior to carbon-ion radiotherapy for liver tumors.. European journal of nuclear medicine and molecular imaging. 2022. DOI: 10.1007/s00259-022-05985-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.