OBJECTIVES

We sought to explore a novel left atrial appendage (LAA) strain parameter which could represent the cumulative adverse impact of chronic Atrial fibrillation (AF) on the LAA function, and the relationship between the LAA strain parameter and thrombosis risk in patients with non-valvular AF.

METHODS

We enrolled 268 patients with non-valvular AF and 58 sinus rhythm subjects who underwent transesophageal echocardiography in the study. LAA longitudinal strain amplitude (LAA LSA) was defined as the sum of the value of the maximum positive peak strain (LAA PLS) and the absolute value of the minimum negative peak strain (LAA NLS). Dense spontaneous echo contrast (SEC) was defined as grade 3 or 4 SEC.

RESULTS

Compared to sinus rhythm group, the global LAA strain parameters were significantly lower in paroxysmal AF (n = 148), and the lowest of them were found in persistent AF (n = 120), which suggested that the global LAA strain parameters could evaluate LAA function in sinus rhythm, paroxysmal AF and persistent AF. Compared with patients in AF without SEC/thrombus (n = 113), the regional and global LAA strain parameters were significantly depressed in AF with SEC/thrombus (n = 155). Multivariate logistic regression analyses showed that LAA global LSA (OR 0.768; 95% CI:0.569, 0.970; p = 0.027) was an independent predicter of the SEC/thrombus. Compared with patients in AF without dense SEC or thrombus (n = 210), the regional and global LAA strain parameters were significantly impaired in the patients with dense SEC/thrombus(n = 58). LAA global LSA (AUC 0.884) had the best predictable accuracy for dense SEC or thrombus, and outperformed LAA PLS, LAA NLS, CHA2DS2-VASc score and conventional LAA functional parameters that have been used in the evaluation blood flow stasis in LAA. LAA LSA showed excellent interobserver and intra-observer agreement beyond LAA PLS and LAA NLS.

CONCLUSION

The novel LAA strain parameters, which were feasible and reproducible parameters for evaluation LAA mechanic function, had good predictive accuracy for blood flow stasis in LAA beyond conventional LAA functional parameters.

Для цитирования: Su Bo, Sun Shi-Kun, Dai Xin-Jia, Ma Chang-Sheng, Zhou Bing-Yuan. The novel left atrial appendage strain parameters are associated with thrombosis risk in patients with non-valvular atrial fibrillation.. Echocardiography (Mount Kisco, N.Y.). 2023. DOI: 10.1111/echo.15578.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.