MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-025-02134-4

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2025

Circular over-the-wire pulsed field ablation for atrial fibrillation: differences in outcomes between conscious sedation or general anesthesia.

Van der Graaf M, Abeln B G S, Van Dijk V F, Liebregts M, Wijffels M C E F, Balt J C, Boersma L V A

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Pulmonary vein isolation (PVI) using pulsed field ablation (PFA) is typically performed under general anesthesia (GA) due to patient discomfort and pain. However, procedures under GA require specialized personnel for airway management. PFA systems with suitable characteristics may enable PFA-procedures to be performed under bolus- administered conscious sedation (CS).

OBJECTIVE

Assess the feasibility, safety, and efficacy of performing PVI with a circular-over-the-wire PFA catheter under CS, compared to GA.

METHODS

We conducted a single-center registry study of atrial fibrillation (AF) patients undergoing an ablation with the circular over-the-wire PFA catheter, between January 29 and December 31, 2024, at the St. Antonius Hospital, The Netherlands. CS was used if no anesthesiology team was available. Endpoints included acute isolation of ablation targets, procedural characteristics and freedom from adverse events.

RESULTS

The analysis included 174 consecutive patients (67.2% male, mean age 62.8 ± 9.3 years), with 62.1% having paroxysmal AF. GA was used in 132 patients (75.9%). There were no differences in baseline characteristics between the groups. Total number of applications was higher in the GA group: 33.0 [IQR 32.0; 36.0] vs. 32.0 [IQR 32.0; 33.0], p < 0.001. Median skin-to-skin procedural time was comparable between groups: GA 39.0 min [IQR 34.0;46.0] vs. CS 42.0 min [IQR 37.5; 46.0], P = N.S. Acute procedural efficacy was 100% in both groups. One patient in the GA group experienced a major bleeding complication.

CONCLUSION

Conscious sedation offers an efficient and safe alternative to general anesthesia for patients undergoing a procedure with use of the circular over-the-wire PFA catheter.

Для цитирования: Van der Graaf M, Abeln B G S, Van Dijk V F, Liebregts M, Wijffels M C E F, Balt J C, Boersma L V A. Circular over-the-wire pulsed field ablation for atrial fibrillation: differences in outcomes between conscious sedation or general anesthesia.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2025. DOI: 10.1007/s10840-025-02134-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.