MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tnnls.2025.3564947

Медицинская библиотека · IEEE transactions on neural networks and learning systems · 2025

RSME: Respiration-Driven Synchronized Motion Estimator for Real-Time Thoracic 3-D CT Reconstruction Using Low-Rank Motion Fields and Dose-Free Surface Imaging.

Wei Ziwen, Wu Xiaolong, Wang Qi, Zhou Yunbiao, Zhai Shaozhuang, Jiang Tao, Liu Zhihua, Zhang Yang, Gu Hongcang, Yuan Shuanghu, Qian Junchao

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Real-time 3-D CT reconstruction during radiotherapy, based on planning 4-D CT, has emerged as a central area of interest in the field of image-guided radiotherapy (IGRT). However, current methodologies still rely on time-consuming patient-specific training, real-time registration, or additional radiation doses. Our contribution, respiration-driven synchronized motion estimator (RSME), represents a novel and efficient forward propagation network, leveraging an explicit spatial-temporal low-rank decomposition of displacement fields and surface imaging to enable real-time 3-D CT reconstruction during respiration. RSME is derived from a well-designed, interpretable inverse optimization problem, mapping static spatial components and dynamic skin depth images to dynamic temporal components for reconstruction. In RSME, we customize two core transformer-based encoders: the motion former (M-Former) and the motion pattern former (P-Former), and incorporate customized cross attention mechanism to effectively gauge the interdependencies between the two encoders. Strategically, we input skin depth images into M-Former to inquire about motion information, thus circumventing the requirement for real-time registration. In P-Former, we introduce static spatial components that integrate explicit respiratory pattern details to distinguish between patients without the necessity for patient-specific training, and harness the static nature to evade additional inference latency. Extensive experimental results demonstrate that RSME achieves comparable or even superior accuracy than state-of-the-art methods, with a cumulative latency of 96 ms. Notably, RSME accomplishes this without necessitating additional radiation dosage, time-consuming patient-specific training or real-time registration.

Для цитирования: Wei Ziwen, Wu Xiaolong, Wang Qi, Zhou Yunbiao, Zhai Shaozhuang, Jiang Tao, Liu Zhihua, Zhang Yang, Gu Hongcang, Yuan Shuanghu, Qian Junchao. RSME: Respiration-Driven Synchronized Motion Estimator for Real-Time Thoracic 3-D CT Reconstruction Using Low-Rank Motion Fields and Dose-Free Surface Imaging.. IEEE transactions on neural networks and learning systems. 2025. DOI: 10.1109/tnnls.2025.3564947.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.