MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjcard.2025.04.027

Медицинская библиотека · The American journal of cardiology · 2025

The Influence of Height on Occupational Radiation Exposure of Interventional Cardiologists During Selective Coronary Angiography Using a Radial Artery Approach.

Casazza Richard, Malik Bilal, Hashmi Arsalan, Fogel Joshua, Montagna Enrico, Gibson Darren, Palacio Andres, Beginyazova Habiba, Frankel Robert, Shani Jacob

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Radiation exposure is one of the most adverse occupational hazards faced by interventional cardiologists. Operator height can influence operator radiation exposure. This single-center retrospective study (n = 534) assessed the cumulative radiation (CR) exposure in μSv and normalized radiation exposure (CR/DAP) using three different ranges of height (short, regular, and tall) of the primary operator at four anatomical locations when using a radial artery approach. A multivariate linear regression analyses for cumulative operator radiation dose found that tall operator height had significantly lesser values than regular operator height for the thorax (p <0.001), abdomen (p = 0.01), left eye (p <0.001), and right eye (p <0.001). Short operator height did not significantly differ from regular operator height. Multivariate linear regression analyses for normalized operator radiation dose found that tall operator height had significantly lesser values than regular operator height for the thorax (p <0.001), abdomen (p = 0.01), left eye (p <0.001), and right eye (p = 0.002). Short operator height did not significantly differ from regular operator height. In conclusion, there was an association of lower operator radiation dose in the thorax, abdomen, left eye, and right eye for tall operators as compared to regular height operators. We recommend regular height operators be exceedingly vigilant with their personal radiation protection techniques. Furthermore, these same protection techniques should be considered with patients that have a higher likelihood of generating greater dose-area-products.

Для цитирования: Casazza Richard, Malik Bilal, Hashmi Arsalan, Fogel Joshua, Montagna Enrico, Gibson Darren, Palacio Andres, Beginyazova Habiba, Frankel Robert, Shani Jacob. The Influence of Height on Occupational Radiation Exposure of Interventional Cardiologists During Selective Coronary Angiography Using a Radial Artery Approach.. The American journal of cardiology. 2025. DOI: 10.1016/j.amjcard.2025.04.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.