MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2463/mrms.mp.2024-0162

Медицинская библиотека · Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2025

High-spatial-resolution Hepatobiliary Phase Imaging Using An Optimized Integrated Combination of Parallel Imaging and Compressed Sensing Technique.

Tsuji Yusuke, Kawai Nobuyuki, Noda Yoshifumi, Tanahashi Yukichi, Nagata Shoma, Kajita Kimihiro, Kato Hiroki, Goshima Satoshi, Yamada Kei, Matsuo Masayuki

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the feasibility of high-spatial-resolution hepatobiliary phase (HBP) imaging using optimized integrated combination with the compressed sensing and parallel imaging technique (Compressed SENSE).

METHODS

Sixty consecutive participants underwent liver MRI and breath-hold HBP imaging using enhanced T1 high-resolution isotropic volume excitation (eTHRIVE; SENSE factor, 1.7; slice thickness/gap, 4/-2 mm; and acquisition time, 20s), eTHRIVE with Compressed SENSE (CS-eTHRIVE4mm; C SENSE factor, 3.45; slice thickness/gap, 4/-2 mm; and acquisition time, 10s), and thin-slice eTHRIVE with Compressed SENSE (CS-eTHRIVE2mm; C SENSE factor, 3.45; slice thickness/gap, 2/0 mm; and acquisition time, 20s). The signal intensity ratio (SIR) and signal-to-noise ratio (SNR) of the liver on each HBP image were calculated. The image quality and conspicuity of hypointense nodules on HBP images were qualitatively assessed. Then, the sensitivity for detecting hypointense nodules was calculated. The quantitative and qualitative parameters of three HBP images were compared.

RESULTS

The SIR of the three HBP images did not differ (P = 0.36). The SNR of CS-eTHRIVE2mm was lower than that of eTHRIVE and CS-eTHRIVE4mm (P < 0.001). CS-eTHRIVE2mm had a better image quality than eTHRIVE and CS-eTHRIVE4mm (P < 0.001). CS-eTHRIVE2mm (97.5%) had a significantly better sensitivity for detecting hypointense nodules on HBP image than eTHRIVE (86.4%) and CS-eTHRIVE4mm (89.0%) (P = 0.001‒0.006).

CONCLUSION

CS-eTHRIVE2mm had an excellent image quality and lesion detectability due to its high-spatial-resolution.

Для цитирования: Tsuji Yusuke, Kawai Nobuyuki, Noda Yoshifumi, Tanahashi Yukichi, Nagata Shoma, Kajita Kimihiro, Kato Hiroki, Goshima Satoshi, Yamada Kei, Matsuo Masayuki. High-spatial-resolution Hepatobiliary Phase Imaging Using An Optimized Integrated Combination of Parallel Imaging and Compressed Sensing Technique.. Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine. 2025. DOI: 10.2463/mrms.mp.2024-0162.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.