From Faster Frames to Flawless Focus: Deep Learning HASTE in Postoperative Single Sequence MRI.

Hosse Clarissa, Fehrenbach Uli, Pivetta Fabio, Malinka Thomas, Wagner Moritz, Walter-Rittel Thula, Gebauer Bernhard, Kolck Johannes, Geisel Dominik

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

This study evaluates the feasibility of a novel deep learning-accelerated half-fourier single-shot turbo spin-echo sequence (HASTE-DL) compared to the conventional HASTE sequence (HASTES) in postoperative single-sequence MRI for the detection of fluid collections following abdominal surgery. As small fluid collections are difficult to visualize using other techniques, HASTE-DL may offer particular advantages in this clinical context.

MATERIALS AND

METHODS

A retrospective analysis was conducted on 76 patients (mean age 65±11.69 years) who underwent abdominal MRI for suspected septic foci following abdominal surgery. Imaging was performed using 3-T MRI scanners, and both sequences were analyzed in terms of image quality, contrast, sharpness, and artifact presence. Quantitative assessments focused on fluid collection detectability, while qualitative assessments evaluated visualization of critical structures. Inter-reader agreement was measured using Cohen's kappa coefficient, and statistical significance was determined with the Mann-Whitney U test.

RESULTS

HASTE-DL achieved a 46% reduction in scan time compared to HASTES, while significantly improving overall image quality (p<0.001), contrast (p<0.001), and sharpness (p<0.001). The inter-reader agreement for HASTE-DL was excellent (κ=0.960), with perfect agreement on overall image quality and fluid collection detection (κ=1.0). Fluid detectability and characterization scores were higher for HASTE-DL, and visualization of critical structures was significantly enhanced (p<0.001). No relevant artifacts were observed in either sequence.

CONCLUSION

HASTE-DL offers superior image quality, improved visualization of critical structures, such as drainages, vessels, bile and pancreatic ducts, and reduced acquisition time, making it an effective alternative to the standard HASTE sequence, and a promising complementary tool in the postoperative imaging workflow.

Для цитирования: Hosse Clarissa, Fehrenbach Uli, Pivetta Fabio, Malinka Thomas, Wagner Moritz, Walter-Rittel Thula, Gebauer Bernhard, Kolck Johannes, Geisel Dominik. From Faster Frames to Flawless Focus: Deep Learning HASTE in Postoperative Single Sequence MRI.. Academic radiology. 2025. DOI: 10.1016/j.acra.2025.05.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.