MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jebdp.2020.101401

Медицинская библиотека · The journal of evidence-based dental practice · 2020

Comparison of Anchorage Efficiency of Orthodontic Mini-implant and Conventional Anchorage Reinforcement in Patients Requiring Maximum Orthodontic Anchorage: A Systematic Review and Meta-analysis.

Liu Yan, Yang Zhen-Jin, Zhou Jing, Xiong Ping, Wang Quan, Yang Yan, Hu Yu, Hu Jiang-Tian

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the clinical effectiveness of mini-implants (MIs) and conventional anchorage appliances used for orthodontic anchorage reinforcement in patients with class I or II malocclusion with bimaxillary protrusion.

MATERIALS AND

METHODS

Literature search was conducted through PubMed, Embase, and Cochrane from inception to July 2018. The following Medical Subject Heading terms were used for the search string: "skeletal anchorage", "temporary anchorage devices", "miniscrew implant", "mini-implant", "micro-implant". Standardized mean difference (SMD) and 95% confidence interval (CI) of horizontal and vertical movements of teeth from baseline were used for comparison.

RESULTS

A total of 12 studies were included in the final analysis. MI group significantly lowered mesial movement of molars compared to conventional anchorage group (SMD = -1.48, 95% CI = -2.25 to -0.72; P = .0002). There was significantly higher retraction of incisors in the MI group than in the conventional group (SMD = -0.47 mm, 95% CI = -0.87 to -0.07; P = .02). No significant difference was seen in vertical movement of molars (SMD = -0.21 mm, 95% CI = -0.87 to 0.45; P = .52) and incisors (SMD = -0.30, 95% CI = -1.18 to 0.58; P = .5).

CONCLUSION

MIs seem to be more effective than the conventional anchorage devices in terms of minimizing unintended mesial movement of molars with maximum retraction of anterior teeth.

Для цитирования: Liu Yan, Yang Zhen-Jin, Zhou Jing, Xiong Ping, Wang Quan, Yang Yan, Hu Yu, Hu Jiang-Tian. Comparison of Anchorage Efficiency of Orthodontic Mini-implant and Conventional Anchorage Reinforcement in Patients Requiring Maximum Orthodontic Anchorage: A Systematic Review and Meta-analysis.. The journal of evidence-based dental practice. 2020. DOI: 10.1016/j.jebdp.2020.101401.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.