MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.transproceed.2020.01.019

Медицинская библиотека · Transplantation proceedings · 2020

Gastroesophageal Reflux and Microaspiration in Lung Transplant Recipients: The Utility of a Single Esophageal Manometry and pH Probe Monitoring Study.

Gualdoni J, Ritzenthaler J, Burlen J, Stocker A, Abell T, Roman J, Nunley D R

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Gastroesophageal reflux (GER) in recipients of lung transplant (LTX) is associated with chronic allograft rejection, presumably via microaspiration that damages airway epithelium. Most LTX programs perform a single post-LTX esophageal study to evaluate for GER; the efficacy of this test is unclear.

METHODS

Patients with 1 year of post-LTX follow-up, including routine bronchoscopies with bronchoalveolar lavage fluid (BALF) samples as well as high-resolution esophageal manometry and pH probe monitoring (HREMpH), were evaluated. BALF samples were analyzed with competitive enzyme-linked immunosorbent assay to detect bile salts, which are indicative of aspiration. These results were compared to results of HREMpH studies post LTX.

RESULTS

Ninety BALF samples were analyzed for bile salts and acted as disease positive for this evaluation. Of the 13 HREMpH cases, 8 were positive for GER, but only 3 were positive for bile salts via assay. Of the 5 HREMpH-negative cases, 2 experienced aspiration. A solitary HREMpH study had 60.0% sensitivity and 37.5% specificity with positive and negative likelihood ratios: 0.96 and 1.07, respectively.

CONCLUSION

Microaspiration appears to be an intermittent phenomenon, and HREMpH screening poorly correlates with BALF evidence of aspiration; which may not be adequate. As aspiration detection is crucial in this population, further analysis is warranted.

Для цитирования: Gualdoni J, Ritzenthaler J, Burlen J, Stocker A, Abell T, Roman J, Nunley D R. Gastroesophageal Reflux and Microaspiration in Lung Transplant Recipients: The Utility of a Single Esophageal Manometry and pH Probe Monitoring Study.. Transplantation proceedings. 2020. DOI: 10.1016/j.transproceed.2020.01.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.