MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/dote/doz093

Медицинская библиотека · Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus · 2020

Vascular pressure bands on high-resolution esophageal manometry with impedance studies.

Lis Steffen, Vachhani Herit, Tanner Samuel, Leopold Andrew, Zitomer Samantha, Bhuta Rajiv, Schey Ron, Malik Zubair, P Parkman Henry

СтатьяПеревод пока не подготовлен

Аннотация

Horizontal pressure bands on high-resolution esophageal manometry with impedance (HREMI) tracings are often seen and thought to be due to cardiovascular structures compressing the esophagus. The aim of this study was to determine the prevalence and location of vascular pressure bands on HREMI studies and correlate these pressure bands to bolus clearance. HREMI studies in supine and upright positions from patients and normal volunteers were reviewed. Pressure bands were defined as bands of horizontal pressure greater than the 20 mmHg isobaric contour. Each swallow was reviewed with impedance to determine if bolus transit was impaired by the band. 38.6% of 251 patients and 36.4% of 11 normal controls had a pressure band present. There were a greater number of bands in supine versus upright position (patients: 130 vs. 25, P < 0.001 and controls: 6 vs. 1). Patients with pressure bands had similar demographics (age, gender, BMI) compared to those without. Average distal contractile integral of bands was greater in supine compared to upright (133 ± 201 vs. 60 ± 148 mmHg cm s, P < 0.05). Bands were commonly located clustered at 46 and 72% of esophageal length. Bolus transit was impaired by bands in 20.4% of supine and 14.0% of upright swallows. Vascular pressure bands can have a prominent appearance on HREMI studies, present in, being more prevalent and having greater pressure in the supine than the upright position. These vascular bands, when present, may impair esophageal transit.

Для цитирования: Lis Steffen, Vachhani Herit, Tanner Samuel, Leopold Andrew, Zitomer Samantha, Bhuta Rajiv, Schey Ron, Malik Zubair, P Parkman Henry. Vascular pressure bands on high-resolution esophageal manometry with impedance studies.. Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus. 2020. DOI: 10.1093/dote/doz093.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.