m+Medelevator.RU
← Поиск публикаций
Anaesthesia · 2019

Reliability of gastric suctioning compared with ultrasound assessment of residual gastric volume: a prospective multicentre cohort study.

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bouvet L, Zieleskiewicz L, Loubradou E, Alain A, Morel J, Argaud L, Chassard D, Leone M, Allaouchiche B, AzuRea CAR'Echo collaborative networks

Аннотация

We aimed to compare the reliability of aspiration via a nasogastric tube with ultrasound for assessment of residual gastric volume. Sixty-one adult patients who were mechanically ventilated and received continuous enteral feeding through a nasogastric tube for > 48 h were included. A first qualitative and quantitative ultrasound examination of the gastric antrum was followed by gastric suctioning, performed by an operator blinded to the result of the ultrasound examination. A second ultrasound examination was performed thereafter, followed by re-injection of the aspirated gastric contents (≤ 250 ml) into the stomach. A third ultrasound assessment was then immediately performed. If the suctioned volume was ≥ 250 ml, 250 mg erythromycin was infused over 30 min. A fourth ultrasound was performed 90 min after the third. Sixty (98%) patients had a qualitatively assessed full stomach at first ultrasound examination vs. 52 (85%) after gastric suctioning (p = 0.016). The calculated gastric volume significantly decreased after gastric suctioning, without a significant decrease in the number of patients with volume ≥ 250 ml. Four of the nine patients with calculated gastric volume ≥ 250 ml had vomiting within the last 24 h (p = 0.013). The antral cross-sectional area significantly decreased between the third and the fourth ultrasound examination (p = 0.015). Erythromycin infusion did not make a significant difference to gastric volume (n = 10). Our results demonstrate that gastric suctioning is not a reliable tool for monitoring residual gastric volume. Gastric ultrasound is a feasible and promising tool for gastric volume monitoring in clinical practice.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты