Transbronchial and transesophageal fine-needle aspiration using an ultrasound bronchoscope in mediastinal staging of potentially operable lung cancer.
Аннотация
OBJECTIVE
We performed this study to evaluate the role of transesophageal endoscopic ultrasound with bronchoscope-guided fine-needle aspiration (EUS-B-FNA) following endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in the mediastinal staging of lung cancer.
METHODS
In this prospective study, we applied transbronchial and transesophageal ultrasonography using an ultrasound bronchoscope on patients with confirmed or strongly suspected potentially operable non-small cell lung cancer. Following EBUS-TBNA, EUS-B-FNA was used for mediastinal nodes that were inaccessible or difficult to access by EBUS-TBNA. The accessibility by EBUS-TBNA and EUS-B-FNA to mediastinal nodal stations having at least one node ≥ 5 mm was also checked.
RESULTS
In 150 patients, we performed EBUS-TBNA and EUS-B-FNA on 299 and 64 mediastinal nodal stations, respectively. Among 143 evaluable patients, EBUS-TBNA diagnosed mediastinal metastasis in 38 patients. EUS-B-FNA identified mediastinal metastasis in three additional patients. Surgery diagnosed mediastinal metastasis in four more patients. The sensitivity, negative predictive value, and diagnostic accuracy of EBUS-TBNA in the detection of mediastinal metastasis were 84.4%, 93.3%, and 95.1%, respectively. These values for the combined approach of EBUS-TBNA and EUS-B-FNA increased to 91.1%, 96.1%, and 97.2%, respectively, although the differences were not statistically significant (P = .332, P = .379, and P = .360, respectively). Among 473 mediastinal nodal stations having at least one node ≥ 5 mm that were evaluated, the proportion of accessible mediastinal nodal stations by EBUS-TBNA was 78.6%, and the proportion increased to 84.8% by combining EUS-B-FNA with EBUS-TBNA (P = .015).
CONCLUSION
Following EBUS-TBNA in the mediastinal staging of potentially operable lung cancer, the accessibility to mediastinal nodal stations increased by adding EUS-B-FNA and an additional diagnostic gain might be obtained by EUS-B-FNA.
TRIAL REGISTRATION: clinicaltrials.gov, NCT00741247.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.