MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/ch-199202

Медицинская библиотека · Clinical hemorheology and microcirculation · 2019

Performance of contrast-enhanced ultrasound (CEUS) compared to MRI in the diagnostic of gallbladder diseases.

Negrão de Figueiredo G, Mueller-Peltzer K, Schwarze V, Zhang L, Rübenthaler J, Clevert D A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Conventional ultrasound and MRI are very important techniques for the detection of gallbladder alterations. In the past years, studies showed that the additional use of contrast media to the conventional ultrasound allows the early depiction of pathological microvessels and their flow elucidating suspect findings stipulating the prompt therapy approach.

OBJECTIVE

The study aims to evaluate the performance of CEUS in gallbladder diseases and compare it to MR imaging using histopathological findings as a gold standard.

MATERIAL AND

METHODS

The retrospective mono-center study analysed 18 patients with gallbladder alterations between 2009 and 2017. All patients underwent CEUS and MRI examinations and all results were confirmed in the pathology. CEUS images were performed and interpreted by a single experienced physician.

RESULTS

CEUS imaging results compared to MR imaging of the gallbladder demonstrated a sensitivity of 100%, specificity of 93%, a positive predictive value of 67% and a negative predictive value of 100%.

CONCLUSION

CEUS enables the depiction and characterization of important vascularization's patterns facilitating the early differentiation between malignant and benign findings. In this study, CEUS displayed a better diagnostic accuracy than MRI proving to be a valuable additional tool to the established imaging modalities.

Для цитирования: Negrão de Figueiredo G, Mueller-Peltzer K, Schwarze V, Zhang L, Rübenthaler J, Clevert D A. Performance of contrast-enhanced ultrasound (CEUS) compared to MRI in the diagnostic of gallbladder diseases.. Clinical hemorheology and microcirculation. 2019. DOI: 10.3233/ch-199202.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.