Gastric juice urease activity as a diagnostic test for Helicobacter pylori infection.
Аннотация
OBJECTIVE
An ideal assay (inexpensive, sensitive, specific, and readily available) for Helicobacter pylori is lacking. Urease activity is an important characteristic of the organism and is employed in the rapid urease and urea breath tests. In this study, we assessed whether a simpler test, namely, measurement of gastric juice urease activity, would provide comparable results.
METHODS
Gastric juice was analyzed for urea and ammonia in 57 patients evaluated with rapid urease test and histology. Urease activity was assessed by the fraction of urea hydrolyzed to ammonia.
RESULTS
Thirty-five subjects were H. pylori positive and 22 were H. pylori negative. Compared with noninfected subjects, H. pylori-positive patients had lower urea levels (0.52 +/- 0.10 vs. 2.77 +/- 0.48 mM, p < 0.01), higher ammonia concentrations (6.59 +/- 1.06 vs. 1.64 +/- 0.25 mM, p < 0.01), and higher gastric urease activity (0.83 +/- 0.03 vs. 0.24 +/- 0.14, p < 0.01). In H. pylori-negative patients, there was a correlation between blood and gastric urea (r = 0.61, p < 0.01). However, in H. pylori-positive patients, no such relationship existed (r = 0.30, p = 0.11). The ratio of gastric to blood urea was lower in infected patients (0.11 +/- 0.02 vs. 0.45+/- 0.04, p < 0.01). The sensitivity and specificity of gastric urease activity for diagnosis of H. pylori were 91% and 100%, respectively, and for the ratio of gastric to blood urea, 89% and 95%, respectively.
CONCLUSION
Gastric juice urease activity is a simple, sensitive, and specific means to detect H. pylori.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.