MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/ice.2024.148

Медицинская библиотека · Infection control and hospital epidemiology · 2024

Dilution dysfunction: evaluation of automated disinfectant dispenser systems in 10 hospitals demonstrates a need for improved monitoring to ensure that correct disinfectant concentrations are delivered.

Cadnum Jennifer L, Kaple Claire E, Eckstein Elizabeth C, Saade Elie A, Ray Amy J, Zabarsky Trina F, Guerrero Bernardino J, Yassin Mohamed H, Donskey Curtis J

СтатьяПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

Automated dispensers that dilute concentrated disinfectants with water are commonly used in healthcare facilities. In a point-prevalence product evaluation, 9 of 10 (90%) hospitals using dilutable disinfectants had 1 or more malfunctioning dispensers. Twenty-nine of 107 (27.1%) systems dispensed product with lower-than-expected concentrations, including 15 (14.0%) with no detectable disinfectant.

Для цитирования: Cadnum Jennifer L, Kaple Claire E, Eckstein Elizabeth C, Saade Elie A, Ray Amy J, Zabarsky Trina F, Guerrero Bernardino J, Yassin Mohamed H, Donskey Curtis J. Dilution dysfunction: evaluation of automated disinfectant dispenser systems in 10 hospitals demonstrates a need for improved monitoring to ensure that correct disinfectant concentrations are delivered.. Infection control and hospital epidemiology. 2024. DOI: 10.1017/ice.2024.148.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.