Gupta Pankaj, Siddiqui Ruby, Singh Shravya, Pradhan Nikita, Shah Jimil, Samanta Jayanta, Jearth Vaneet, Singh Anupam, Mandavdhare Harshal, Sharma Vishal, Mukund Amar, Birda Chhagan Lal, Kumar Ishan, Kumar Niraj, Patidar Yashwant, Agarwal Ashish, Yadav Taruna, Sureka Binit, Tiwari Anurag, Verma Ashish, Kumar Ashish, Sinha Saroj K, Dutta Usha

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To apply CT-based deep learning (DL) models for accurate solid debris-based classification of pancreatic fluid collections (PFC) in acute pancreatitis (AP).

MATERIAL AND

METHODS

This retrospective study comprised four tertiary care hospitals. Consecutive patients with AP and PFCs who had computed tomography (CT) prior to drainage were screened. Those who had magnetic resonance imaging (MRI) or endoscopic ultrasound (EUS) within 20 days of CT were considered for inclusion. Axial CT images were utilized for model training. Images were labelled as those with≤30% solid debris and >30% solid debris based on MRI or EUS. Single center data was used for model training and validation. Data from other three centers comprised the held out external test cohort. We experimented with ResNet 50, Vision transformer (ViT), and MedViT architectures.

RESULTS

Overall, we recruited 152 patients (129 training/validation and 23 testing). There were 1334, 334 and 512 images in the training, validation, and test cohorts, respectively. In the overall training and validation cohorts, ViT and MedVit models had high diagnostic performance (sensitivity 92.4-98.7%, specificity 89.7-98.4%, and AUC 0.908-0.980). The sensitivity (85.3-98.6%), specificity (69.4-99.4%), and AUC (0.779-0.984) of all the models was high in all the subgroups in the training and validation cohorts. In the overall external test cohort, MedViT had the best diagnostic performance (sensitivity 75.2%, specificity 75.3%, and AUC 0.753). MedVit had sensitivity, specificity, and AUC of 75.2%, 74.3%, and 0.748, in walled off necrosis and 79%, 74.2%, 75.3%, and 0.767 for collections >5 cm.

CONCLUSION

DL-models have moderate diagnostic performance for solid-debris based classification of WON and collections greater than 5 cm on CT.

Для цитирования: Gupta Pankaj, Siddiqui Ruby, Singh Shravya, Pradhan Nikita, Shah Jimil, Samanta Jayanta, Jearth Vaneet, Singh Anupam, Mandavdhare Harshal, Sharma Vishal, Mukund Amar, Birda Chhagan Lal, Kumar Ishan, Kumar Niraj, Patidar Yashwant, Agarwal Ashish, Yadav Taruna, Sureka Binit, Tiwari Anurag, Verma Ashish, Kumar Ashish, Sinha Saroj K, Dutta Usha. Application of deep learning models for accurate classification of fluid collections in acute necrotizing pancreatitis on computed tomography: a multicenter study.. Abdominal radiology (New York). 2024. DOI: 10.1007/s00261-024-04607-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.