MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.scib.2026.06.046

Медицинская библиотека · Science bulletin · 2026

An EMI-suppressed, high-fidelity Janus bioelectrode with gradient impedance for accurate dual-biosignal-based motion recognition.

Yao Qizhi, Yang Wenke, Shen Yangyang, Yan Huan, Hu Hengrui, Zhan Pengfei, Liu Hu, Liu Chuntai, Shen Changyu

СтатьяПеревод пока не подготовлен

Аннотация

Accurate acquisition of bioelectrical signals like electromyography (EMG) and electrocardiography (ECG) is essential for wearable health monitoring and human-machine interaction, yet remains severely compromised by electromagnetic interference (EMI) in ubiquitous electronic environments. To address this, a gradient-impedance Janus bioelectrode is engineered for high-fidelity, EMI-suppressed dual-biosignal sensing. This asymmetric architecture integrates a carbon nanotubes (CNTs)/NiFe2O4/thermoplastic polyurethane (TPU) magnetic-dielectric aerogel with a highly conductive liquid-metal textile, establishing a continuous impedance gradient from the skin interface to the external ambient. This design enables a synergistic absorption-reflection-reabsorption mechanism, yielding an exceptional shielding effectiveness of 64 dB with low reflection (R < 0.24). By stabilizing the local electromagnetic field and minimizing interfacial impedance, the electrode achieves reliable EMG/ECG monitoring with a signal-to-noise ratio of 16.6 dB under strong EMI. Moreover, a machine-learning framework leveraging fused dual-signal features attains 97.7% accuracy in human motion recognition, substantially surpassing single-modality approaches. This work introduces a signal-integrity-driven paradigm that unifies electromagnetic field management with physiological sensing, paving a general way toward EMI-resilient, high-precision bioelectronics.

Для цитирования: Yao Qizhi, Yang Wenke, Shen Yangyang, Yan Huan, Hu Hengrui, Zhan Pengfei, Liu Hu, Liu Chuntai, Shen Changyu. An EMI-suppressed, high-fidelity Janus bioelectrode with gradient impedance for accurate dual-biosignal-based motion recognition.. Science bulletin. 2026. DOI: 10.1016/j.scib.2026.06.046.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.