MedElevator Войти в исследования
← Поиск публикаций

DOI 10.64898/2026.06.26.26356692

Медицинская библиотека · medRxiv : the preprint server for health sciences · 2026

A Real-World Evaluation of Failure Detection for Liver CT Segmentation.

Bennett Jeddy, Woodland McKell, Castelo Austin, Altaie Mais, Anthony Ajith, Siddiqi Noreen S, Long James P, Brock Kristy K

СтатьяПрепринтПеревод пока не подготовлен

Аннотация

Deep learning models deployed in clinical imaging frequently encounter distribution shifts, yet most out-of-distribution (OOD) detection methods are evaluated only on controlled research datasets. As a result, it is unclear whether existing approaches can reliably identify segmentation failures that arise in real-world clinical practice. We evaluated six OOD detection methods on a deployed liver CT segmentation model (3D nnU-Net) using internal data from 400 patients and external data from 100 patients collected across nearly 70 sites in 7 countries. One method was Pairwise Surface DSC, a surface-based extension of Pairwise DSC, that we introduced. OOD performance was measured using sensitivity, AUROC, and balanced accuracy, with thresholds determined on an independent cohort of 400 patients using the Youden J statistic. Statistical significance was assessed using McNemar tests and stratified bootstraps (α = 0.05) with Benjamini-Hochberg correction. Pairwise Surface DSC was the top-performing method, with perfect sensitivities (1.00), near-perfect AUROCs (0.97 internal; 1.00 external), and the highest balanced accuracies (0.94 internal; 0.88 external; p < 0.001). These results show that automated failure detection for liver CT segmentation is clinically feasible and that Pairwise Surface DSC is a promising candidate for deployment. Our code is available at https://github.com/mckellwoodland/liver_ct_ood_translation.

Для цитирования: Bennett Jeddy, Woodland McKell, Castelo Austin, Altaie Mais, Anthony Ajith, Siddiqi Noreen S, Long James P, Brock Kristy K. A Real-World Evaluation of Failure Detection for Liver CT Segmentation.. medRxiv : the preprint server for health sciences. 2026. DOI: 10.64898/2026.06.26.26356692.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.