MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1741-2560/13/1/016002

Медицинская библиотека · Journal of neural engineering · 2015

Long-term decoding of movement force and direction with a wireless myoelectric implant.

Morel Pierre, Ferrea Enrico, Taghizadeh-Sarshouri Bahareh, Audí Josep Marcel Cardona, Ruff Roman, Hoffmann Klaus-Peter, Lewis Sören, Russold Michael, Dietl Hans, Abu-Saleh Lait, Schroeder Dietmar, Krautschneider Wolfgang, Meiners Thomas, Gail Alexander

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

The ease of use and number of degrees of freedom of current myoelectric hand prostheses is limited by the information content and reliability of the surface electromyography (sEMG) signals used to control them. For example, cross-talk limits the capacity to pick up signals from small or deep muscles, such as the forearm muscles for distal arm amputations, or sites of targeted muscle reinnervation (TMR) for proximal amputations. Here we test if signals recorded from the fully implanted, induction-powered wireless Myoplant system allow long-term decoding of continuous as well as discrete movement parameters with better reliability than equivalent sEMG recordings. The Myoplant system uses a centralized implant to transmit broadband EMG activity from four distributed bipolar epimysial electrodes.

APPROACH: Two Rhesus macaques received implants in their backs, while electrodes were placed in their upper arm. One of the monkeys was trained to do a cursor task via a haptic robot, allowing us to control the forces exerted by the animal during arm movements. The second animal was trained to perform a center-out reaching task on a touchscreen. We compared the implanted system with concurrent sEMG recordings by evaluating our ability to decode time-varying force in one animal and discrete reach directions in the other from multiple features extracted from the raw EMG signals.

MAIN

RESULTS

In both cases, data from the implant allowed a decoder trained with data from a single day to maintain an accurate decoding performance during the following months, which was not the case for concurrent surface EMG recordings conducted simultaneously over the same muscles.

SIGNIFICANCE: These results show that a fully implantable, centralized wireless EMG system is particularly suited for long-term stable decoding of dynamic movements in demanding applications such as advanced forelimb prosthetics in a wide range of configurations (distal amputations, TMR).

Для цитирования: Morel Pierre, Ferrea Enrico, Taghizadeh-Sarshouri Bahareh, Audí Josep Marcel Cardona, Ruff Roman, Hoffmann Klaus-Peter, Lewis Sören, Russold Michael, Dietl Hans, Abu-Saleh Lait, Schroeder Dietmar, Krautschneider Wolfgang, Meiners Thomas, Gail Alexander. Long-term decoding of movement force and direction with a wireless myoelectric implant.. Journal of neural engineering. 2015. DOI: 10.1088/1741-2560/13/1/016002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…