MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/njms.njms_63_25

Медицинская библиотека · National journal of maxillofacial surgery · 2026

Innovative use of syringe plunger to secure contrast medium during indirect sinus lift: A technical note.

Saxena Mohit, Chauhan Himanshu, Tandon Parul, Tiwari Shamita, Baruah Pranami

СтатьяПеревод в очереди

Аннотация

The indirect sinus lift for maxillary sinus augmentation is a common, less invasive solution for placing dental implants. However, the patency of the membrane not to get perforated during the procedure is questionable. A contrast medium, for example, Iohexol, held in the osteotomy site, can be a great guide to ensure membrane integrity. In this technical note, we present an innovative use of the syringe plunger as a stop to hold the contrast media in the osteotomy site in indirect sinus lift procedures.

Для цитирования: Saxena Mohit, Chauhan Himanshu, Tandon Parul, Tiwari Shamita, Baruah Pranami. Innovative use of syringe plunger to secure contrast medium during indirect sinus lift: A technical note.. National journal of maxillofacial surgery. 2026. DOI: 10.4103/njms.njms_63_25.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.