MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/hon.1022

Медицинская библиотека · Hematological oncology · 2011

Endoscopic ultrasonography in gastric lymphomas: appraisal on reliability in long-term follow-up.

Vetro Calogero, Romano Alessandra, Chiarenza Annalisa, Conticello Concetta, Donnarumma Daniela, Gorgone Ausilia, Coppolino Francesco, Palumbo Giuseppe Alberto, Bonanno Giacomo, Di Raimondo Francesco

СтатьяПеревод пока не подготовлен

Аннотация

The reliability of endoscopic ultrasonography (EUS) in follow-up management of gastric lymphomas has not been clearly validated. We conducted a retrospective analysis on 23 patients, 12 affected by mucosa-associated lymphoid tissue (MALT) lymphoma, eight by diffuse large B-cell lymphoma, and three by high-grade lymphoma with low-grade component, all treated with a stomach-conservative approach. One hundred and twenty matched evaluations with both EUS and endoscopy with biopsy (E-Bx) were performed, according to validated guidelines and clinical judgment. At a median follow-up of 87 months ranged between 9.5 and 166 months, the analysis of progression-free survival and disease-free survival showed a strict relationship between the persistence of EUS abnormalities and the clinical outcome in patients with MALT lymphoma (p = 0.0079; p = 0.02) but not in patients with high-grade lymphoma. In conclusion, EUS evaluation does not seem reliable in follow-up management of high-grade lymphomas, although it could have a great clinical impact in the management of MALT lymphoma.

Для цитирования: Vetro Calogero, Romano Alessandra, Chiarenza Annalisa, Conticello Concetta, Donnarumma Daniela, Gorgone Ausilia, Coppolino Francesco, Palumbo Giuseppe Alberto, Bonanno Giacomo, Di Raimondo Francesco. Endoscopic ultrasonography in gastric lymphomas: appraisal on reliability in long-term follow-up.. Hematological oncology. 2011. DOI: 10.1002/hon.1022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.